BASIC OPERATIONS
Use the following settings and connections to operate this camera with a system controller (sold separately) .
1
Make connections with all equipment turned off.
2
After referring to “INSTALLATION METHOD” Step 3 (See
p00), remove the power supply unit and set the dip
switches on the camera’s circuit board. (See p00)
•
Terminate setting (System control setting switches):
Initial setting is ON. When several cameras are connected
together, the last camera in the series should be set to ON
and the other cameras set to OFF.
(System controller settings):
Set the TERMINATE position (ON/OFF) of the
“ADDRESS/TERMINATE” dip switches on the back panel.
•
Baud rate (System control setting switches):
Initial setting is 19200bps. To set a different baud rate,
change the switches to the appropriate settings.
(System controller settings):
Set the baud rate at the “BAUD RATE SET” item on the
menu screen.
Note: Be sure the controller and the camera are set to the
same baud rate.
•
Address setting (Address setting switches):
Initial setting is all switches to “0”. The address can be set
from 0 to 127. To set an address, refer to “ADDRESS
SETTING TABLE” and then move the switches. (See p00)
(System controller settings):
Set the ADDRESS position (1 – 3) of the
“ADDRESS/TERMINATE” dip switches on the back panel.
3
Install the power supply unit and turn on power to all
equipment.
When the power is turned on, the camera will perform its
startup movements. The camera’s address will flash on the
monitor screen.
4
Operation of the camera with the system controller
Operation methods are described below. For detailed
information about operation, see the instruction manual of the
system controller.
Type of camera operation with the system controller
Direct input from “CAMERA” keypad buttons.
This operation makes needed adjustments to the camera’s
basic settings according to photographic factors such as
light compensation and shutter speed.
The FUNCTION button on the system controller
enables selection a command from 5 types of call-up
commands.
(Call-up commands)
•
ALARM OUT
•
L-L PHASE
•
ZOOM PRESET
•
RESET
•
PRESET MEMORY
Note: Group operation enables setting and operation of groups
1 – - 15. Do not use group 0 (ALL) or category “ALL”.
CAMERA ADDRESS
001
(Example)
“CAMERA” keypad
camera commands
Numeric keypad
FUNCTION button
English
– 7 –