Remove the plastic cover (A) and then the 
tape (B) fixing the lens.
Put back the plastic cover (A), and turn it 
clockwise until you hear it click to securely 
lock it.

Before Installing the Unit

INSTALLATION MANUAL

Color CCD Camera

Install these units securely according to this installation 
manual. Be aware that allowing them to fall may cause 
personal injury.
This installation should be made by a qualified service 
person and should conform to all local codes.

Product Lineup  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Surface Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

In-ceiling Mount (Closed Type)  . . . . . . . . . . . . . . . . . . 3

In-ceiling Mount (Open Type) . . . . . . . . . . . . . . . . . . . . 4

Connections and Settings  . . . . . . . . . . . . . . . . . . . . . . 5

Address Settings Table . . . . . . . . . . . . . . . . . . . . . . . . . 7

Pattern Sheet (inserted at the end of this manual)

CAUTION: 

For VA-80S (Power Borard Unit)

ALL-POLE MAINS SWITCH with a contact separation of 
at least 3mm in each pole shall be incorporated in the 
electrical installation of the building.

Important

• Be careful when opening holes for installing the unit. 

Work with the power and video cables pulled out for 
easy installation.

• Make sure to properly perform waterproofing for the 

ceiling where you are installing the unit.

• Make sure that the surface in the installation location 

has no unevenness and is strong enough to bear the 
total weight of the unit.

• Install this unit in an environment where the 

temperature range stays between -10°C/+14°F and 
+50°C/+122°F (no condensation allowed).

Contents

E

ngl

is

h

L5BU2_XE(INSTALLATION).book  0 ページ  2007年8月1日 水曜日 午前11時7分

Summary of Contents for VCC-9500

Page 1: ...eiling Mount Closed Type 3 In ceiling Mount Open Type 4 Connections and Settings 5 Address Settings Table 7 Pattern Sheet inserted at the end of this manual CAUTION For VA 80S Power Borard Unit ALL POLE MAINS SWITCH with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building Important Be careful when opening holes for installing the u...

Page 2: ...P Attachment VA 80A Outdoor Housing VA 80EX Surface Cover VA 80F Clear Dome Cover VA CM8C Smoked Dome Cover VA CM8S Indoor Type Outdoor Type In ceiling Mount Surface Mount P3 P4 P2 Refer to the instruction manual supplied with each product Refer to the instruction manual supplied with each product Power Board Unit VA 84S for AC24V VA 80S for AC230V Power Board Unit VA 84S for AC24V VA 80S for AC23...

Page 3: ...lue on the camera unit and the power board unit and push the camera unit until they click 8Align the arrows H of the same color blue on the inner side of the surface cover and the power board unit and fix the cover by rotating it clockwise How to attach the drop prevention cable accessory 1 Peel off the two sided tape K at the end of the cable and attach it to the hook L on the inner side of the s...

Page 4: ... bracket top hook F 5Connect the video cable and pass the connection cables through the bracket 6Insert the bracket into the ceiling hole and fix it using screws G 2 places 7Connect the cables and set the switches See Connections and Settings on page 5 8Align the arrows C of the same color blue on the camera unit and the inner side of the bracket and push the camera unit until they click 9Align th...

Page 5: ...he connection cables through the slit in the dust sheet E and connect the video cable 7Insert the bracket into the ceiling hole and fix it using screws F 2 places 8Connect the cables and set the switches See Connections and Settings on page 5 9Align the blue sticker B on the bracket and the arrow B of the same color on the camera unit and then push the camera unit until they click ÀAlign the SANYO...

Page 6: ...fter connection always install the supplied power terminal cover A for safety reasons Ground Neutral Live Monitor Connection Supported coaxial cables Using different cables from those specified here may attenuate the video and or sync signals and interfere with correct transmission RG 59U coaxial cables can be used when distance between devices is short but not in duct or aerial routing Cable type...

Page 7: ...m input output cables Video cable A RS 485 B DO NOT CONNECT TO PHONE LINE 1 IN OUT MONITOR OUT MON2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAIN VIDEO A B TELEMETRY 1 16 Video input terminal Camera Camera Video input terminal Monitor sold separately Video input terminal Terminator switch Communication conversion connectors System controller sold separately Digital video recorder sold separately L5BU2...

Page 8: ...88 m m m m 61 189 m m m m m 62 190 m m m m m 63 191 m m m m m m 64 192 m 65 193 m m 66 194 m m 67 195 m m m 68 196 m m 69 197 m m m 70 198 m m m 71 199 m m m m 72 200 m m 73 201 m m m 74 202 m m m 75 203 m m m m 76 204 m m m 77 205 m m m m 78 206 m m m m 79 207 m m m m m 80 208 m m 81 209 m m m 82 210 m m m 83 211 m m m m 84 212 m m m 85 213 m m m m Address Camera No Switch No Protocol SANYO PELCO...

Page 9: ...Pattern Sheet 186 7 3 166 6 5 4 φ4 5 0 2 P D φ168 6 6 Scale 1 1 Unit mm inch L5BU2_XE INSTALLATION book 0 ページ 2007年8月1日 水曜日 午前11時7分 ...

Page 10: ...L5BU2_XE INSTALLATION book 1 ページ 2007年8月1日 水曜日 午前11時7分 ...

Page 11: ...MEMO L5BU2_XE INSTALLATION book 2 ページ 2007年8月1日 水曜日 午前11時7分 ...

Page 12: ... recyclé Impreso en papel reciclado Gedruckt auf Recyclingpapier 使用再生纸印刷 1AC6P1P3149 A L5BU2 XE 0807KP HS SANYO Electric Co Ltd Printed in China b Dimensions 156 6 1 71 2 8 φ136 5 4 Unit mm inch L5BU2_XE INSTALLATION book 1 ページ 2007年8月1日 水曜日 午前11時7分 ...

Reviews: