8
-
2. ADJUSTMENT
2-1. Table for Servicing Tools
1. Calibration software
Download the calibration software and the firmware from the
following URL.
http://www.overseas.sanyo.com/dcamera_service/
Place the DscCalDi.exe file, camapi32.dll file and
QrCodeInfo.dll file together into a folder of your choice.
2. Pattern box
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100
± 20 K and luminosity to 900 ± 20 cd/m
2
. Be careful of han-
dling the lump and its circumference are high temperature
during use and after power off for a while.
2-2. Setup
1. System requirements
Windows 2000 or XP or Vista
IBM® -compatible PC with pentium processor
USB port
2. Video monitor
Connect the video output to a video monitor with an input
impedance of 75 ohms.
2-3. Adjustment Items and Order
1. AWB Adjustment
2. CMOS White Point Defect Detect Adjustment
3. CMOS Black Point And White Point Defect Detect Adjust-
ment In Lighted
4. Focus Assistance Drive Adjustment
5. CS Mount Optical Axis Adjustment
Note: If the lens, CMOS and board and changing the part, it
is necessary to adjust again. Item 1-5 adjustments should be
carried out in sequence.
2-4. Connecting the camera to the computer
1. Connect the camera’s USB terminal to the computer’
USB connector.
2. It turns on power while pushing the FAR button and the
SET button of the operation panel.
3. Double-click on the DscCalDi.exe.
4. L5DJ2 is selected with Model_Code.
5. PAL (VCC-HD2300P) or NTSC (VCC-HD2300) is
selected with Video_Mode.
2-4-1. Computer screen during adjustment
2-4-2. Operation buttons
Ref. No.
Name
Part code
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
VJ8-0190
VJ8-0192
VJ8-0191
VHJ-0196
VHJ-0197
VHJ-0198
Pattern box
Calibration software
Chroma meter
Spare lump (pattern box)
Standard lens
Standard lens
C-CS adapter
Siemens star chart
Number
1
1
1
1
1
1
1
1
Firmware
QrCode
AWB
Focus
UV Matrix
R Bright
RGB Offset
Tint
B Bright
Gain
Phase
LCD
Calibration
Upload
Initialize
LCD Type
H AFC
Test
VCOMDC
VCOMPP
Cal Data
Cal Mode
OK
OK
EVF
USB storage
Get
Set
VID
Set
PID
Set
Serial
Set
Rev.
Set
Setting
Language
Video Mode
VCO
Factory Code
Backrush pulse :
Set
Get
Model_Code
Summary of Contents for VCC-HD2300 - Full HD 1080p Network Camera
Page 40: ...SIEMENS STAR CHART ...