11
-
11. It checks that click DT SW and a white point disappears
completely.
12. Click WDD checks white point compensation being
performed and disappearing.
3-13. High Temperature White point correction
Adjustment location:
Computer screen
Measuring location:
VIDEO OUT
Measuring equipment:
Monitor display, Spot heater,
Radiation temperature gauge
Adjustment method:
1. Shield light with a blackout curtain and the box to provide
dark condition.
2. Switch to the adjustment software and display the
adjustment screen.
3. Use the spot heater to evenly heat the underside of the
sensor to 75°C.
4. Press the “ ” key to move to WDD, and then click
“AUTO” in white spot correction mode. The correction will
be carried out and the results will be displayed.
5. Carry out white spot correction three times at “AUTO”.
6. Switch to the WDDL5CS software and display the
adjustment screen.
7. Click the Manual in MODE.
8. Click the START.
9. Please pile up a false white point and a white point.
10. It checks that click DT SW and a white point disappears
completely.
11. Click WDD checks white point compensation being
performed and disappearing.
3-12. Normal Temperature White point correction
Adjustment location:
Computer screen
Measuring location:
VIDEO OUT
Measuring equipment:
Monitor display
Adjustment method:
1. Shield light with a lens cap to provide dark condition.
2. Click the WDDL5CS software installed from the personal
computer, and the adjustment window will be displayed.
3. Click the Auto in MODE.
4. Click the “INPUT No.”, Input number is input.
5. Click the Color in FILTER.
6. CMOS number is input to CCD No. column.
7. Push the ENTER kye.
Adjustment starts and a result is displayed.
8. Click the Manual in MODE.
9. Click the START.
10. Please pile up a false white point and a white point.
Please Input Serial No.
White Defect = ooo,ooo
************
*****
Please Adjust...
Summary of Contents for VCC-WD8870P