– 21 –
2. AWB Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Set a distance of 2
±
1 cm between the pattern box and the
camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the
“CHECK", “CHECK_ND”, "MS", “MS_M” and “IRIS” values.
If CHECK= wc0, wc1, wc2, CHECK_ND= wnc0, wnc1, wnc2,
MS= ms1, ms2, MS_M= ms3, ms4 and IRIS= s1, s2, s3, s4,
s5, the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
wc0=128
±
2, wc1=128
±
2, wc2=130
±
40
wnc0=128
±
2, wnc1=128
±
2, wnc2=130
±
40
1401<ms1<=3600, 801<ms2<=2500, 1251<ms3<=3100,
1201<ms4<=2900
100<=s1<=220, 100<=s2<=220, 100<=s3<=220,
100<=s4<=220, 100<=s5<=220
ms2<ms4<ms3<ms1
s1>s2>s3>s4>s5
Adjustment values other than the above are irrelevant.
3. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
4. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set a distance of 2
±
1 cm between the pattern box and the
camera.
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect
will appear.
Dsc Calibration
x
OK
AWB Results:
1:
WB=239,496,402
CHECK=128,128,143
WB_ND=237,495,401
CHECK_ND=128,128,141
IRIS=177,162,145,127,120
MS=2139,1154
MS_M=1638,1437
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1
Copy
Camera
Pattern box
(color viewer)
Camera
Pattern box
(color viewer)