– 14 –
3-6. Adjust Specifications
[CP1 board (Side B)]
Note:
1. Frequency adjustment is necessary to repair in the CP1
board and replace the parts.
2. Power voltage sets about +3.0 V.
Preparation:
1. Remove the cabinet back and holder monitor. You can see
VR501 and CL518 in the CP1 board.
Note: LCD flexible flat cable and backlight lead wire keep
connecting. When assembling, holder monitor and
metal part of LCD panel should not contact a sub-
strate or solder the lead wire at CL518, and screw the
holder monitor.
2. Insert the SD card.
3. Turn on the power switch, and set the camera mode.
1. IC501 Oscillation Frequency Adjustment
Adjustment method:
1. Adjust with VR501 to 502.5
±
1 kHz.
2. Lens Adjustment
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux
±
10 %.
Adjustment method:
1. Set the siemens star chart 100 cm
±
3 cm so that it be-
comes center of the screen.
2. Double-click on the DscCalDi.exe.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the "STD
AFPOS", "FOCUS" and “ZOOM” values.
If FOCUS=focus1, focus2, focus3, focus4, focus5 and the ad-
justment values fulfill the conditions below, they are determined
as within specifications.
Adjustment value determination
960<=STD_AFPOS<=1050
-30<=focus1<=+40
-40<focus2<+60
-50<=focus3<=+80
-70<=focus4<=+100
-100<=focus5<=+120
0<=zoom<=130
Measuring Point
ADJ. Location
Measuring Equipment
ADJ. Value
CL518
Frequency counter
VR501
502.5
±
1 kHz
CL404
GND
CL518
VR501
Camera
Siemens
star chart
DscCalDi
x
OK
Focus Result
STD_AFPOS=1005
FOCUS=1,9,24,30,20
ZOOM=77
!
Summary of Contents for Xacti VPC-S1
Page 25: ......