– 15 –
3. AWB Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the 2nd
line "AGC", 5th line "CHECK" and 6th line "MS" values.
If AGC=a1, a2, a3, a4, CHECK=wc0, wc1, wc2 and MS=MS1,
MS2 and the adjustment values fulfill the conditions below, they
are determined as within specifications.
Adjustment value determination
a1<70, a2<120, a3<180, a4<240
wc0=128
±
2
wc1=128
±
2
wc2=130
±
40
2600<=MS1<=4300
2900<=MS2<=4600
Adjustment values other than the above are irrelevant.
4. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect
will appear.
6. LCD Panel Adjustment
[CP1 board (Side B)]
Camera
Pattern box
(color viewer)
Camera
Pattern box
(color viewer)
CL404
GND
CL518
VR501
Dsc Calibration
x
OK
AWB Result:
1:
AGC=59,109,160,209
3F_AGC=1,1
WB=263,509,648
CHECK=127,128,141
MS=3537,3807
SENSE=0
IRIS=0