137
0. 0
~
100.0s
10.0
After voltage feedback disconnection, the duration time before protection action.
F5.24
limit voltage of voltage feedback disconnection
0.0
~
100.0
%
* motor rated voltage
80.0%
This function code defines the maximum output voltage of VFD. When output feedback disconnection happens and
voltage increases without control and lost protection, this function can limit the output voltage within the allowed range,
which ensures the safe of work load.
F6 analog and impulse parameters of input and output
F6.00
AI1 input corresponding physical quantity
0
~
2
0
0
:
speed command
(
output frequency, -100.0%
~
100.0%
)
1
:
torque command
(
output torque, -200.0%
~
200.0%
)
AI1 analog setting value works as torque command value, given torque range is -200.0%
~
200.0%. Relevant
setting see F6 group function code description.
2
:
voltage command
(
output voltage, 0.0%
~
200.0%*motor rated voltage
)
F6.01
AI1 input lower limit
0.00V/0.00mA
~
10.00V/20.00mA
0.00
F6.02
AI1 lower limit corresponding physical quantity setting
-200.0%
~
200.0%
0.0%
F6.03
AI1 input upper limit
0.00V/0.00mA
~
10.00V/20.00mA
10.00
F6.04
AI1 upper limit corresponding physical quantity setting
-200.0%
~
200.0%
100.0%
F6.05
AI1 input filtering time