152
20
:
Acc/Dec time selection TT2
By selecting the ON/OFF combination of these function terminals, there would be 4 kinds of acc/dec time at most, as
showed in the following table:
Acc/Dec time
selection
terminal 2
Acc/Dec time
selection
terminal 1
Acc/Dec time selection
OFF
OFF
Acc time 1/Dec time 1
OFF
ON
Acc time 2/Dec time 2
ON
OFF
Acc time 3/Dec time 3
ON
ON
Acc time 4/Dec time 4
21
:
run command channel 1
22
:
run command channel 2
By selecting the ON/OFF combination of these function terminals, there would be 3 kinds of run command channels
and 4 kinds of methods at most, as showed in the following table.
Run command
channel selection
terminal 2
Run command
channel
selection
terminal 1
Run command channel
OFF
OFF
Determined by function code
P0.06
OFF
ON
0
:
keypad
ON
OFF
1
:
terminal
ON
ON
2
:
communication
23: Acc/Dec prohibit
When this terminal is valid, VFD will maintain current frequency without influence of external signal (except stop
command).