Notes: 

This is a two person installation.

All marks made on tile, marble or fiberglass should be made lightly in 

pencil so they can be removed after the installation is complete.  An 

optional method is to use masking tape on the walls and sill that can be 

removed as the installation progresses.

1

 

Establish Centerlines – The centerlines of the unit must be established 

on the shower sill and on the walls as well.  Measure the width of 

the shower sill and mark the centerline down the middle.  Transfer the 

centerline to the walls using a level.  Mark Header Bar [D] location at 2” 

less than the unit height, on the centerline.  Measure, and write down, the 

distance between the two Wall Mount marks.  

2

 

Bar Mount –

 

Drill the Wall Mount holes 5/16”.  Insert the Wall Anchors 

[A] fully into the holes. Place the Wall Mount Blocks [B] against the 

wall with the counter bore to the middle of the enclosure. Using the 1/4 x 

2” Truss head screws [C], attach the Wall Mount Block to the wall, with the 

slot in a vertical position and the screw centered in the block.

3

 

Bar Length - Measure the width of the fixed glass panel [F].  Subtract 

2 3/8” from that dimension.  Measure from the center of the middle 

hole in the bar to the fixed panel end of the bar and cut that end off (The 

fixed panel end is the one with the second hole in it).  Now subtract 

1 3/4” from the measurement taken in step 1, which is the overall 

width of the shower opening at the top.  Then take that measure 

from the newly cut end of the bar to the uncut end and cut that 

end off of the bar.

4

 

Level the Bar – Temporarily place the Wall Mount Sleeves [E] on each 

end of the Header Bar.  Align the Header Bar with the Wall Mount 

Block, and slide the Wall Mount Sleeves over the Wall Mount Blocks.  Place 

a level on the center of the Header Bar and check for level.  If needed the 

Wall Mount Blocks can be raised, or lowered to make the Header Bar level.  

Once leveled, remove the Header Bar from the Wall Mount Blocks, and the 

Wall Mount Sleeves from the Header Bar. 

 NOTE:

  A slight downward tilt 

on the door side of the Header Bar will help keep the door in the closed 

position while in use.  A downward tilt on the Fixed Panel side will cause 

the door to open, allowing water leakage.

FOOT PRINT -  

The width of the Door unit's base is 2 1/16" 

Consider these measurements before drilling. 

_

_

Summary of Contents for Alumax ProLine PL70

Page 1: ...INSTALLATION INSTRUCTIONS ProLine PL80 HEAVY FRAMELESS BYPASS BATH ENCLOSURE Copyright Alumax Bath Enclosures 2013 All rights reserved G03980849 5 1 13 ...

Page 2: ...upport a person s weight and could break c Do not use excessive force when opening and closing the enclosure Excessive force can lead to glass breakage or other damage to the enclosure Make sure wall jamb bumpers are securely fastened in place per the installation instructions GLASS USAGE AND HANDLING WARNINGS a TEMPERED GLASS CANNOT BE CUT Attempting to cut tempered glass will result in the glass...

Page 3: ...enter Guide Insert O Center Guide Screws P Door Panel Q Roller Back Plate R Back Plate Sleeve S Back Plate Gasket T Mid Plate Gasket U Mid Plate V Roller Plate W Roller Screw X Anti Jump Y Anti Jump Screw Z Glass Mount Threaded Rod AA 5 16 x 3 4 Socet Cap Screw BB Glass Mount CC Glass Mount Washer DD Glass Mount Bushing EE Glass Mount Cap FF Stopper GG Stopper Screw HH Wall Mount Set Screw I I Wal...

Page 4: ...h Measure the width of the fixed glass panel F Subtract 2 3 8 from that dimension Measure from the center of the middle hole in the bar to the fixed panel end of the bar and cut that end off The fixed panel end is the one with the second hole in it Now subtract 1 3 4 from the measurement taken in step 1 which is the overall width of the shower opening at the top Then take that measure from the new...

Page 5: ...orrect locations Align the Threshold so that it is straight Tape it down in a few spots and lightly trace the inside edge Remove the tape Threshold and Glass Clips Run a bead of caulk approximately 1 8 outside of the mark you just made Replace the Threshold and fasten the Glass Clips to the sill Install the Vinyl Inserts K into the Glass Clips CAUTION Tape the threshold down to keep it from being ...

Page 6: ... Fixed Panel with the holes facing up Using a thin rod or straightened wire coat hanger push the Glass Mount Threaded Rods Z into the end of the Header Bar and line one up with each hole in the bar Put a 5 16 x 3 4 Socket Cap Screw AA through the Glass Mount BB and snug it down into a rod inside the Header Bar DO NOT TIGHTEN Place a Glass Mount Washer CC on top of the Glass Mount Repeat for the ot...

Page 7: ...EN 10Door Panel Installation Lift the Door Panel P and place the rollers on the bar making sure to get the bottom edge of the Door Glass into the Center Guide To adjust the door glass height Adjustments must be made to the Bar height Adjustments can be made in the wall mount blocks See step 4 as well as the Glass Mounts Once you have the Header Bar set as you want it and the Fixed Panel positioned...

Page 8: ... roller on the strike side of the door making sure that the bottom of the stopper will clear the top of the door glass Tighten the Stopper Set Screw GG Move the door to the open position with the handle 1 4 1 2 from hitting the fixed panel Slide the other stopper over until it just touches the bottom of the roller on the fixed side of the door Tighten the Stopper Set Screw 13Finishing Up Make sure...

Page 9: ...INSTALLATION INSTRUCTIONS ProLine PL60 PL70 PL80 OPTIONAL RETURN PANEL Copyright Alumax Bath Enclosures 2013 All rights reserved G03000000 7 1 13 ...

Page 10: ... use of bathrooms vary widely Alumax does not control the selection of product configurations operating hardware or glazing materials and assumes no responsibility for such ALUMAX DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY ...

Page 11: ...breaking or shattering USE CAUTION WHEN HANDLING GLASS PANELS Safety tempered glass is very resistant to breakage but it can still break if unequal pressure is placed on it during installation or if cutting of the glass is attempted In addition the sharp corners of the panels can damage tile and floor coverings or cause injury BEFORE BEGINNING INSTALLATION Unpack your unit carefully and inspect fo...

Page 12: ...7 A SC 658 Wall Jamb B Wall Jamb Screw C Wall Jamb Anchor D Glass Clip Anchor E Return Threshold F Glass Clip G Glass Clip Screw H Glass Clip Vinyl I Glass Return Panel Not Supplied by Alumax PL RETURN PARTS LIST ...

Page 13: ...r the Wall Jamb Screws B not supplied by Alumax you are using to mount the Wall Jamb to the wall There is a v groove down the middle of the channel on the inside of the profile to help keep the holes centered Drill one hole in the middle and the other two should be drilled six inches from each end Countersink the holes if a flat head screw is being used 3Mark the Wall Jamb Location Place the SC 65...

Page 14: ...return centerline plus 1 1 16 Once properly cut place the Return Threshold on the sill next to the holes you drilled in step 4 with the square end against the return wall Transfer the hole locations to the threshold Notch or drill a 3 8 hole for the screws to pass through Place the threshold on the sill and place the Glass Clips over it aligned with the holes Tape the threshold in place and lightl...

Page 15: ...lass into the Glass Clips 8Install the return mount through the hole in the return glass panel A PL60 return mount is shown for reference Things to Remember There are two things to take into account during the installation of the front of the shower door There will only be one wall mount bracket used The other support for the header bar being the return mount step 8 The threshold for the front of ...