User Manual & Datasheet V 2.1
8
Mechanical Specification
For Mechanical Specification please refer Table 1
PARAMETER
VALUE
Housing
Cast aluminium weather and Flame proof suitable for
mounting in hazardous area Gas Group IIA and IIB as per
IS-2148
Mounting
•
Integral with sense rod or probe with SS /MS(plated)
•
Screw - 1"/1 1/2" BSP/NPT (M)
•
Flanged - (As per your order)
Cable Entry
2 X 1/2"/3/4" BSP/NPT, Brass
Gland type
Double Compression Gland
Sensing
Fully or Partially Teflon Coated Rod, Flexible Probe SS316
Stilling Tube
Pipe, GI / SS
Overall Dimensions
Please refer enclosed probe drawing
Table 1: Mechanical Specifications
9
Electrical Specification
For Electrical Specification please refer Table 2
PARAMETER
VALUE
Mains
•
Capvel-BT : 9V to 55V DC
•
Capvel-ICT : 9V to 30V DC
Power Consumption
•
Capvel-BT : Max. 0.5 watt @12 V
•
Capvel-ICT : Max. 1 watt @12 V
Table 2: Electrical Specifcations
10
Measurement Specification
For Measurement Specification please refer Table 3
PARAMETER
VALUE
Measurement Span
15 to 3000 pf above Zero
Response Time
0.5 to 5 secs.( Adjustable )
Accuracy
+/- 1% FSL or better
Electronics Ambient Temp.
0
◦
C. to
+60
◦
C
Fail-Safe Feature
Reverse Calibratable (Low Level: 20 mA, High Level: 4
mA)
Table 3: Measurement Specifications
Sapcon Instruments Pvt.Ltd.
R
6