The usage of indicator light
If heating indicator light is ON that indicates heating at the moment.
3.
Regular cleaning of nozzle
Open the nozzle and put it upside down under the high pressure faucet until it is clean
enough.
Failure analysis and Troubleshooting:
Trouble
Possible reason
Shooting way
Water is not hot
The power plug is detached,
disconnected power or the
water pressure is too low.
Check the power supply, the water
pressure and keep the water
pressure not lower than 0.04MPa.
Water with low
temperature
The water pressure is too high,
or the power supply is too low.
Adjust unit to allow the water to
run out slowly.
Water with high
temperature
The water pressure is too low,
or inlet or outlet blockage.
Check the water pressure, clean the
inlet and outlet.
Indicator light does not
work.
The water pressure is too low
or circuit fault.
Please contact local service agent.
Technical specification:
Model: SP-7100-IEF
Voltage range: 220-240V~, 50Hz,
Rated power input: 3000W
Protection against electric shock: Class I
IP code: IP24
Dismantle nozzle
High-pressure