SP-MAN-INSTALL-01
Revision 2 21-12-21
12
6.4
Air Intake Adaptor Position and Appliance Panel Access Knock-outs
The EOGB Sapphire air intake adaptor is supplied in the accessory box However to utilise the rear option, the exit flue knock-out in the
rear panel would have to be removed, For this, please follow steps 1,2,3, & 9. If, however, a side or top flue exit is required
(See Fig 9)
,
then the air adaptor would also have to be repositioned. Please follow steps 1-11
1.
Remove top access panel.
2.
Loosen the rear/side panel securing bolts
(see Fig 8)
3.
Remove the rear panel
4.
Loosen the 4 x air intake adaptor securing bolts and remove the intake and gasket.
(see Fig 9)
5.
Remove the chosen exit flue manifold sealing plate by removing the 4 x bolts, plate and gasket
(see Fig 11)
6.
Re-fit the flue manifold sealing plate and gasket to the rear manifold exit.
7.
Reroute the air intake ducting (as shown in FIG 9 for each exit option)
8.
Then fit the air intake adaptor using the same 4 x securing bolts and gasket. (Ensure that the flue securing clamps have been
fitted for the correct orientation
(see Fig 9)
9.
Then depending on the flue exits type required, the appropriate knock-outs can be removed. At the same time, access knock
outs for the Flow, Return, Condensate and Fuel Supply lines can also be knocked out.
(see Fig 10)
10.
Refit the side, rear and top casing panels
11.
Fit the balanced flue as per flue instructions
Fig.8
Fig.9
Fig.11
Fig.10
Appliance Installation