SECTION 3
PART#
49-057 REV K
SAPPHIRE SCIENTIFIC RAGE
®
23
12. At the end of the work day, rinse out the
waste tank with fresh water. Microban QGC
cleaner as the best product for cleaning and
sanitizing the waste tanks as well as other parts
of the system
13. Clean the vehicle interior, unit, tools, hoses
etc., as needed. Inspect
ALL
equipment and
accessories for any damage, leaks, wear, etc.
FREEZE PROTECTION
!
If the unit is exposed to freezing weather
conditions, the water inside of the unit may
freeze, resulting in SERIOUS DAMAGE to
the unit. The following is recommended to
prevent this from occurring during the cold
weather season:
1. Always park the unit in a heated building when
not in use.
2. While out in operation, avoid long periods of
shut down as the unit generates heat while
running.
3. If a heated building is not available, winterize
the unit with anti-freeze.
It is not possible to winterize units that have
auxiliary water tanks. If the unit has an auxiliary
water tank(s), it must be stored in a heated
building.
WINTERIZING YOUR UNIT WITH ANTI-
FREEZE:
1. Shut off the water supply to the unit and
disconnect the water inlet hose from the water
box.
2. Connect all solution hoses and a tool to the
console.
3. Start the unit.
4. Fill the water box with one gallon
of 100%
glycol based anti-freeze.
5. Start the unit and set the throttle control cable
to the idle position. Insure the water pump is on.
Open a tool valve until anti-freeze comes out of
the tool. Repeat this procedure with
ALL
remaining tools and hoses.
6. After the tools and solution hoses have been
filled with anti-freeze, disconnect and store them.
Recover all anti-freeze that comes out of the
tools and hoses and store in an approved
container. ALWAYS re-use or re-cycle anti-
freeze.
7. Prime the chemical injection system with a
100% glycol based antifreeze. Insert the chemical
inlet and prime tube into the anti-freeze
container. Turn the chemical valve to
PRIME
until anti-freeze comes out of the prime hose.
Turn the chemical valve to the
ON
(chemical)
position. Ensure that the flow meter indicates
flow while the attached tools solution valves are
opened. Ensure that all anti-freeze that comes out
of the chemical hose goes into an approved
container.
After
25 seconds
, turn the chemical valve to the
OFF
position.
8. Allow the unit to run for at least
3 minutes
.
The unit is now winterized.
REMOVING ANTI-FREEZE FROM THE
UNIT:
1. Connect the solution hoses to the unit, with a
tool attached to the opposite end. Start the unit.
Turn the water pump on. Open the tool valve and
ensure that the anti-freeze goes into an approved
container. Allow the anti-freeze to flow into the
container until all anti-freeze has been drained.
2. Fill the water box with fresh water and repeat
step 1.
3. Connect the water inlet hose to the unit and
turn the water supply on. Connect all tools and
solution hoses that were winterized to the
solution outlet connection.
Summary of Contents for rage
Page 1: ...Service and Operation Manual 2604 Liberator Dr Prescott AZ 86301 1 928 445 3030...
Page 16: ...SECTION 2 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 12 DIMENSIONAL DIAGRAM REAR MOUNT TANK...
Page 17: ......
Page 46: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 40 CONSOLE ASSEMBLY DETAIL 1...
Page 47: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 41 CONSOLE ASSEMBLY DETAIL 2...
Page 48: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 42...
Page 49: ...SECTION PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 43 69 544 ASSY BEZEL AND PANEL 1 16...
Page 50: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 44 69 445 ASSY BEZEL AND PANEL 17 25...
Page 51: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 45...
Page 52: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 46 69 710 VACUUM PUMP ASSEMBLY...
Page 53: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 47 69 432 ASSEMBLY VACUUM RELIEF...
Page 57: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 51 69 260 MANIFOLD BLOCK ASSEMBLY...
Page 63: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 57 ELECTRICAL DIAGRAM...
Page 64: ...SECTION 5 PART 49 057 REV K SAPPHIRE SCIENTIFIC RAGE 58 HOSE IDENTIFICATION FLOW DIAGRAM...