background image

CA UTIONS,  READ  IT  CA REFULLY  BEFORE  INSTALL ATION

Warning

Constraint

Forbidden

1

2

62

.5

19

3

23

6

22

.5

67.5 80

255

Pd = P - 80

20

25

10

32

10.5

20

10

250

3

4-M6

186

35

115

4-

8.5

45

21

40

17

5

20

25

10

32

110

2-M5

120

10.5

40

40

37

.5

15

5

180

23

20

12

0

2.5

25

12

78

2-

M

5

25

19

15

Dimension figures of Ceiling Installation Part 

1. Only qualified trained person can conduct the isntallation, otherwise it might cause product damage, 

properties damage or even death.  

2. Must ensure the installing fixture spots (ceiling or wall) and hanging device can bear at least 4 times of 

product's net weight, otherwise it might cause accidental crash that lead to product damage, properties 
damage or even death.   

3. Do not connect electric power while installation or unfinished installation, otherwise it might cause product 

damage, properties damage or even death.  

4. Only qualified electrician can conduct electric power installation, otherwise it might cause product damage, 

electric shock or even death. 

5. Only plug with ground wire is acceptable. 

6. Distance P1 must be exactly the same as P, otherwise it might cause product functional fail or damage. 

7. After installation, do not connect electric power until ensure the whole screen is in the same horizontal line 

and fixed stickers of the screen bottom bar has been removed.  

8. Do not expose to hard light or laser for screens with IR remote control and screens with RF remote control 

need to avoid from fluorescent lamp, LED light or hight electromagnetic radiation environment or device. 

9. Please prevent screens from wet place to avoid electric or fire dangerous. 

10. Please keep the screen from hot sources, such as radiator, heating machine, fireplace, loudspeaker or other   
      relative device. 

11. Please unplug the connector at thundering day, raining day or no operation for a long time. As long as the 
      plug is connected with the power sources, the screen is connecting with electricity. 

12. Only accessories from authorized suppliers is acceptable. 

13. Do not put or hang any objects on the screen casing or bottom bar. 

Accessories

Ceiling Installation Part(2 pcs)

Hanger(4pcs) 

Rj45 Plug (1pc) 

Flat Network 
Control Cable 
Lock(1pc) 

Cable Lock(2pcs) 

M8x20mm 
Hexagonal 
Screw(14pcs)  

M8 Screw 
Nut(14pcs) 

Φ8.5 Washer
(2pcs)

M6x10mm
Screw(4pcs)

M5x10mm 
Screw(4pcs)  

Installation

1. Separately put the 2pcs Ceiling Installation Part to left and right side, using 4pcs M6x10mm Screws to fixe Cable Box on the left side 
   Ceiling Installation Part. Figure 1.  

Figure 1

M6x10mm 
Screw(4pcs)

Left Side

Preset 3pcs 

M8x20mm 

Hexagonal 

Screws

Preset 

screws 

for strap

Preset 

screw for 

Brake 

Machanism 

Pay attention to Hanger's 

installing direction

Figure 2

Right Side

Preset 

screw for 

Brake 

Machanism 

Preset 

screws 

for strap

Pay attention to Hanger's 

installing direction

Figure 3

2. Preset 3pcs M8x20mm Hexagonal Screws to 2pcs Hanger, then use M8x20mm Hexagonal 

Screws to install the 2pcs Hanger on to left side Ceiling Installation Part, Figure 2, ensure 
screws are fully tightened. Install the rest 2pcs Hanger to the right side Ceiling Installation 
Part, Figure 3.  

Notices: Preset M8x20mm Hexagonal Screws on hangers is necessary, otherwise the Cable 

Box will block the installation. Please pay attention to the installing direction of Hanger on left 
and right sides, need to be the same as Figure 2 and Figure 3. 

3. Use M5x10mm Screws and Cable Lock to fix cable, Figure 4
4. If Wall Switch or Central Control is necessary, needed to install network control cable. Firstly, 

connect RJ45 Plug with network control cable, then fix RJ45 Plug to the left gap of left side 
Ceiling Installation Part, also use Cable Lock to fix network control cable.  After that put Flat 
Cable that come from Cable Box into RJ45 plug. Figure 5. 

5. Install Brake Machanisms onto preset screws for both sides and ensure screws and screw 

nuts were tightened. Pay attention to the difference of  installing place and direction for left 
and right sides. Figure 6.   .

Cable

Fixed by Cable Lock

Figure 4

Figure 5

Rj45 Plug

Fixed by Cable Lock

network 

control 

cable

Flat Network Control 

Cable Lock

Flat Network 

Control Cable

M5x10 Screw 

Figure 6

Φ8.5 Washer

Installing places for 

Brake Machanism 

(onto nearer the center 

Hangers) 

The direction of Brake Machanism

6. Measure the distance between the center of two Straps, mark as P, correct to mm. Ensure the distance P1 between the center of two 

Hangers for Straps is exactly the same as P, only ±20mm error is adjustable, after that use Tapping Screws to install the 2pcs all set 
Ceiling Installation Parts onto concrete ceiling. Figure 7.

Figure 7

Concrete Ceiling

M10x80mm 

Tapping Screw 

Left side Ceiling 

Installation Part 

Right side Ceiling 

Installation Part 

Adjustable for ±20mm error

Distance between the center 

of two Hangers for Straps, P1

Distance between the center 

of two Straps, P

The distance between hangers on ceiling 

should be strictly the same as the distance 

between two strapes

Warning

Constraint

Warning

Warning

Warning

Constraint

Warning

Constraint

Constraint

Constraint

Constraint

Constraint

Constraint

Reviews: