CA UTIONS, READ IT CA REFULLY BEFORE INSTALL ATION
Warning
Constraint
Forbidden
1
2
62
.5
19
3
23
6
22
.5
67.5 80
255
Pd = P - 80
20
25
10
32
10.5
20
10
250
3
4-M6
186
35
115
4-
8.5
45
21
40
17
5
20
25
10
32
110
2-M5
120
10.5
40
40
37
.5
15
5
180
23
20
12
0
2.5
25
12
78
2-
M
5
25
19
15
Dimension figures of Ceiling Installation Part
1. Only qualified trained person can conduct the isntallation, otherwise it might cause product damage,
properties damage or even death.
2. Must ensure the installing fixture spots (ceiling or wall) and hanging device can bear at least 4 times of
product's net weight, otherwise it might cause accidental crash that lead to product damage, properties
damage or even death.
3. Do not connect electric power while installation or unfinished installation, otherwise it might cause product
damage, properties damage or even death.
4. Only qualified electrician can conduct electric power installation, otherwise it might cause product damage,
electric shock or even death.
5. Only plug with ground wire is acceptable.
6. Distance P1 must be exactly the same as P, otherwise it might cause product functional fail or damage.
7. After installation, do not connect electric power until ensure the whole screen is in the same horizontal line
and fixed stickers of the screen bottom bar has been removed.
8. Do not expose to hard light or laser for screens with IR remote control and screens with RF remote control
need to avoid from fluorescent lamp, LED light or hight electromagnetic radiation environment or device.
9. Please prevent screens from wet place to avoid electric or fire dangerous.
10. Please keep the screen from hot sources, such as radiator, heating machine, fireplace, loudspeaker or other
relative device.
11. Please unplug the connector at thundering day, raining day or no operation for a long time. As long as the
plug is connected with the power sources, the screen is connecting with electricity.
12. Only accessories from authorized suppliers is acceptable.
13. Do not put or hang any objects on the screen casing or bottom bar.
Accessories
Ceiling Installation Part(2 pcs)
Hanger(4pcs)
Rj45 Plug (1pc)
Flat Network
Control Cable
Lock(1pc)
Cable Lock(2pcs)
M8x20mm
Hexagonal
Screw(14pcs)
M8 Screw
Nut(14pcs)
Φ8.5 Washer
(2pcs)
M6x10mm
Screw(4pcs)
M5x10mm
Screw(4pcs)
Installation
1. Separately put the 2pcs Ceiling Installation Part to left and right side, using 4pcs M6x10mm Screws to fixe Cable Box on the left side
Ceiling Installation Part. Figure 1.
Figure 1
M6x10mm
Screw(4pcs)
Left Side
Preset 3pcs
M8x20mm
Hexagonal
Screws
Preset
screws
for strap
Preset
screw for
Brake
Machanism
Pay attention to Hanger's
installing direction
Figure 2
Right Side
Preset
screw for
Brake
Machanism
Preset
screws
for strap
Pay attention to Hanger's
installing direction
Figure 3
2. Preset 3pcs M8x20mm Hexagonal Screws to 2pcs Hanger, then use M8x20mm Hexagonal
Screws to install the 2pcs Hanger on to left side Ceiling Installation Part, Figure 2, ensure
screws are fully tightened. Install the rest 2pcs Hanger to the right side Ceiling Installation
Part, Figure 3.
Notices: Preset M8x20mm Hexagonal Screws on hangers is necessary, otherwise the Cable
Box will block the installation. Please pay attention to the installing direction of Hanger on left
and right sides, need to be the same as Figure 2 and Figure 3.
3. Use M5x10mm Screws and Cable Lock to fix cable, Figure 4
4. If Wall Switch or Central Control is necessary, needed to install network control cable. Firstly,
connect RJ45 Plug with network control cable, then fix RJ45 Plug to the left gap of left side
Ceiling Installation Part, also use Cable Lock to fix network control cable. After that put Flat
Cable that come from Cable Box into RJ45 plug. Figure 5.
5. Install Brake Machanisms onto preset screws for both sides and ensure screws and screw
nuts were tightened. Pay attention to the difference of installing place and direction for left
and right sides. Figure 6. .
Cable
Fixed by Cable Lock
Figure 4
Figure 5
Rj45 Plug
Fixed by Cable Lock
network
control
cable
Flat Network Control
Cable Lock
Flat Network
Control Cable
M5x10 Screw
Figure 6
Φ8.5 Washer
Installing places for
Brake Machanism
(onto nearer the center
Hangers)
The direction of Brake Machanism
6. Measure the distance between the center of two Straps, mark as P, correct to mm. Ensure the distance P1 between the center of two
Hangers for Straps is exactly the same as P, only ±20mm error is adjustable, after that use Tapping Screws to install the 2pcs all set
Ceiling Installation Parts onto concrete ceiling. Figure 7.
Figure 7
Concrete Ceiling
M10x80mm
Tapping Screw
Left side Ceiling
Installation Part
Right side Ceiling
Installation Part
Adjustable for ±20mm error
Distance between the center
of two Hangers for Straps, P1
Distance between the center
of two Straps, P
The distance between hangers on ceiling
should be strictly the same as the distance
between two strapes
Warning
Constraint
Warning
Warning
Warning
Constraint
Warning
Constraint
Constraint
Constraint
Constraint
Constraint