Page:24
3
.
25
—
Command 57: Enable/Disable Managers and Supervisors to Open the Lock in
Manager / Employee Mode
When the lock is in Manager/Employee mode, the lock can be setup to allow the Managers and Supervisors to open the
lock. By default, Managers and Supervisors can enable & disable the lock. Command 57 allows Managers and
Supervisors to open the lock in Manager/Employee mode or disable this ability. This can be completed by performing
the following steps:
Example
Step 1
Enter: 5 7 *
Step 2
Enter: 2-digit Programmer PIN position (00) #
♪♪♪♪♪
Step 3
Enter: 1 #
♪♪♪
Step 4
Enter: 1 #
♪♪♪
(OPTION 1
–
managers/supervisors can open the lock, 0
–
managers/supervisors cannot open the lock)
Step 1
Enter: 5 7 *
Step 2
Enter: 0 0 1 2 3 4 5 6 #
♪♪♪♪♪
Step 3
Enter: 1 #
♪♪♪
Step 4
Enter: 1 #
♪♪♪
The Manager/Supervisor now has the ability to open the lock in Manager/Employee mode.
3
.
26
—
Command 73: Set Date
You must set the date in order to use the Service Mode functions or the audit trail functions. The date should be entered
in DDMMYY format, where DD = day, MM = month, and YY = year. The Date should be set when the lock is first set up and
prepared for use. To set the date, perform the following steps:
Step 1 Enter: 7 3 *
Step 2 Enter: 8-digit Programmer PIN Code (00)#
♪♪♪♪♪
Step 3 Enter: Date in DDMMYY format #
♪♪♪
Step 4 Enter: Date in DDMMYY format #
♪♪♪
Example
Set Date
Enter Code
********
Enter Date
DD/MM/YY
**/**/**
Confirm Date
DD/MM/YY
**/**/**
To set the date as May 25, 2017 (using the factory default Codes):
Step 1 Enter: 7 3 *
Step 2 Enter: 0 0 1 2 3 4 5 6 #
♪♪♪♪♪
Step 3 Enter: 2 5 0 5 1 7 #
♪♪♪
Step 4 Enter: 2 5 0 5 1 7 #
♪♪♪
Set Date
Enter Code
********
Enter Date
DD/MM/YY
25/05/17
Confirm Date
DD/MM/YY
25/05/17