Table A: Programmer Code
PIN
Position
Position
Description
Activity
00
Programmer Code
Cannot open lock
Cannot add/delete other PIN codes
Can change their PIN codes
Can be used to program the lock
functions (audit downloads, time delay,
set time & date)
Table B: User Groups
PIN
Position
Position
Description
Activity
01 - 03
Managers
Open the lock
Add new users
Delete users
Start time delay (when programmed)
Change their PIN code
04 - 09
Supervisors Open the lock
Delete users
Start time delay (when programmed)
Change their PIN code
10 - 29
Users
Open the lock
Start time delay (when programmed)
Change their PIN code
NOTE:
Managers can enable/disable (manager/employee mode)
Supervisors can enable/disable (manager/employee mode)
2.3 Beep Patterns
The following table lists the beep patterns that will be heard when using the
USB Audit Lock 2.0
Beep 1 = Sound emitted when any single button is pressed
Beep 2 = Lower pitch than beep 1
Action/Condition
Tone & Keypad LED
LED
Color
Duration
Normal condition
-
-
-
Each keystroke
(1) beep 1
-
1 cycle
Low battery
(2) beep 1
Red
5 cycles
Battery too low
(20) beep 1
Red
1 cycle
Tamper indication
(3) beep 1 + (3) beep 1
+ (3) beep 1
Red
2 cycles
Start time delay
(3) quick beep 1
Red
1 cycle
Time delay countdown
(1) beep 1
Red
Every 10 seconds
Time delay expired
(10) quick beep 1
Green
1 cycle
Opening window
countdown
(2) beep 1
Green
Every 10 seconds
Bolt extension
(1) beep 2 + (1) beep 1
Red
1 cycle
Code input - lock in
penalty time
(2) brap
Red
1 cycle
Code input - lock disabled (2) beep 2
Red
1 cycle
Enable lock (manager/
employe mode)
(4) beep 1
Green
1 cycle
Disable lock (manager/
employee mode)
(2) beep 2
Red
1 cycle
Access to program modes (5) beep 1
Green
1 cycle
Program argument
confirmation
(3) beep 1
Green
1 cycle
Program complete
(3) beep 1
Green
1 cycle
Mode 77 - PIN used
(1) beep 2
Red
1 cycle
Mode 77 - PIN empty
(1) brap
Red
1 cycle
Wrong input/
Access denied
(1) brap
Red
1 cycle
5
CAUTION: During normal entry, do not wait more than 10 seconds between
entries or the lock will clear and you will have to start over.