20
Sargent and Greenleaf
Revision 02/15/2022 Document: 630-600
3.19 — Command 96: Battery Verification
The A-Series lock’s Battery health can be audibly retrieved. The battery health is measured in terms Good, Should be Replaced and
Bad.
•
Good batteries indicates the lock is operating properly.
•
Should be replaced means the lock is operating but batteries should be replaced soon.
•
Bad indicates the lock is not operating properly and batters must be replaced before continuing.
You can verify the lock’s battery health serial using the following process.
Enter: 96* on the lock keypad
Battery health
3.20 — Command 97: Date Verification
The A-Series lock’s time and date settings can be audibly retrieved when there is not any visual indicator available. The lock will give
a series of low beep and high beeps that represent the lock format of DDMMYY HHmm. You can verify the lock time and date setting
by using the following process.
Enter: 97* on the lock keypad
DATE:23/01/22 11:23 AM
3.21 — Command 00: Manual secure mode.
The A-Series lock can be configured to operate a “Manual Secure Mode.” IN this mode, it requires the user to enter the 00# to obtain
bolt extension after a successful bolt retraction. The mode is intended to mimic the operation of a manual dial lock. To set the lock
in manual secure mode, use the following process.
3 beeps
Good
5 sets of 2 beeps
Should be replaced
20 beeps
Bad
23
2 low, 3 high
01
1 low, 1 high
22
2 low, 2 high
9
1 low, 1 high
11
1 low, 1 high
23
2 low, 3 high
Process
Set mode on/off
1) Enter: 00*
1) Enter: 00*
2) Enter: Programmer Code + #
♪♪♪♪♪
2) Enter: 00123456 #
♪♪♪♪♪
3) Enter: 1/0 (on/off) + #
♪♪♪
3) Enter: 1/0 (on/off) + #
♪♪♪
4) Enter: 1/0 (on/off) + #
♪♪♪
4) Enter: 1/0 (on/off) + #
♪♪♪