9
630-600
MODEL 6128/6129 PROGRAMMING & OPERATIONS GUIDE
2.4 — User Access Modes and Opening the Lock
Multiple User —
The lock can be opened by entering any valid code other than the Programming
Code . If time delay is activated, any valid code (except the Programming Code) can be entered to
start the time delay . Then any valid code (except the Programming Code) can be entered during
the opening window to open the lock .
Manager/Employee —
The Group Officers or Administrators enable/disable the access by the
User Codes . When in this mode the Group Officer and Administrator Codes do not open the lock .
To enable your lock in Manager/Employee mode
Enter: Your 2-digit Officer/Administrator PIN position
Your 6-digit Officer/Administrator PIN Code
#
x x x x
Lock is enabled for use by User PIN positions .
To disable your lock in Manager/Employee mode
Enter: Your 2-digit Officer/Administrator PIN position
Your 6-digit Officer/Administrator PIN Code
#
x x
Lock is disabled for use by User PIN positions .
Dual Control —
Two valid codes are required to make any programming changes or to open
the lock . These may be either User or Officer/Administrator Codes . The second code must be
entered within 60 seconds after entry of the first code . If time delay is activated, only one code
is required to start the time delay, but both codes must be entered during the opening window to
open the lock .
Time Delay —
The lock may be programmed with a time delay from 0 - 99 minutes with an
opening window of 1minute to 10 minutes .
If your lock does not use the time delay
Enter: Your 2-digit PIN position
Your 6-digit PIN Code
#
x x x
After the beeps, turn the safe handle to the unlocked position within 6 seconds .
2.3.3 — Additional Actions/Conditions for Service Mode
Action/Condition
Tone & Keypad LED KEB LEDs
Duration
Lockout initiated
3 brap
Red + Amber
1 cycle
Service Mode initiated
Amber
Duration of SM Activity
3 beep
2
+ 2 beep
1
Secure condition —
prompt user
Amber + flash
Green
1 cycle - flash
until timeout
Prompt user
for input
1 beep
1
Amber + flash
Green
1 cycle - flash until
timeout
Lock initialization
successful
1 beep
1
Green + Amber
1 cycle
Lock initialization
failed
2 brap
Red + Amber
1 cycle