MODEL 6128/6129 PROGRAMMING & OPERATIONS GUIDE
3.2 — Command 28: Audit Download
The 6128/29 Lock Audit Trail can store as many as 400 time and date events . Some
examples of events are:
• Adding or deleting a User code .
• Changing a code .
• Opening or closing the lock . (Bank and Service Mode Users)
• Programming commands, such as setting the date . (Bank and Service Mode Users)
The audit trail can be downloaded to a Touch Memory key and uploaded to a computer
using the Sargent and Greenleaf Comptronic Lock Management System software . Complete
instructions are provided with the software .
To download the Audit Trail, perform the following 4 steps:
Step 1.
Enter:
2 8 *
Step 2.
Enter: 2-digit Programmer PIN position (00)
6-digit PIN Code followed by #
Step 3.
Enter: 8 digit cipher code and # as described in the Lock Management
software instructions .
Step 4.
Press the silver face of the Touch Memory Key into the corresponding
port (the round depression) on the keypad extension . The touch key will snap into
place and will be retained .
The yellow LED will remain on while the audit trail is downloading to the Touch Memory
Key . This takes about 20 seconds .
The lock beeps 3 times
x x x
when the download is complete .
If you hear an error beep (one long continuous beep), the audit
trail was not downloaded properly . You must start the download
over, beginning with Step 1 .
After you’ve successfully downloaded the audit trail information
into the Touch Key, follow the Lock Management System
instructions provided with the Lock Management System
software to upload the data to your computer .
3.3 — Command 32: Setting the Access Mode
The lock may be set for Multiple User, Manager/Employee, or Dual Control Modes .
Multiple User
— The lock can be opened by entering any valid code, except for the
Programming Code .
Manager/Employee
— The Group Officers or Administrators enable/disable the access of
individual User Codes . When in this mode, the Group Officer and Administrator Codes do not
open the lock .
Dual Control —
Two valid User Codes are required to make any programming changes or
to open the lock . These may be either User or Manager Codes . The second code must be
entered within 60 seconds after entry of the first code . If time delay is activated, only one
code is required to start the time delay, but both codes must be entered during the opening
window to open the lock .