14 1-800-810-WIRE • www.sargentlock.com • A8152C
Copyright © 2014, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
12/20/13
IN120 Cylindrical Lock
10 Outside Reader Installation
Fig. 10A
Outside of Door
1. Orient the reader so the LED lens is at the top.
2. Feed the cable/connector through the door (from outside to inside).
3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Hold the reader flush against door while ensuring proper alignment.