background image

Sargent Electrical Services Ltd. 

 

Copyright 2005 

Issue 03 

Page 10 of 11 

12 May 2005 

 

5  TECHNICAL DATA & APPROVALS 

5.1  Outline Specification 

INPUT 230v 

230 Volts / 0 to 16 Amps 

+ / - 10% 

OUTPUT 230v 

RCD protected, 3 x MCB outputs of 10, 10 and 6A via 2 x 
9 way connectors 

 

INPUT 12v 

2 x 20A battery inputs via a single 6 way connector 

 

OUTPUT 12v 

20A total output via 4 x 16A switched channels protected 
by 7 fused outputs via a 15 way connector 

 

Integrated CHARGER 

Input 110-240 Volts AC +/- 10%, Frequency 50 Hz +/- 6%, 
Current 3.15A max. 

DC Output 13.5 Volts nominal, Current 16 Amps max (200 
Watts). 

 

Signal INPUT 

4 x Fresh water level, 2 x Waste water level, 1 x Engine 
running via a 8 way connector 

Fresh water negative sensed 

Waste water negative sensed 

Data IN / OUT 

Data communication and power to Control Panel via 20 
way IDC header connector 

 

IP rating 

IP31 

 

Operating 

temperature 

Ambient 0 to 35° Centigrade 

PSU case temperature with full load 65° C Max 

Automatic shutdown and restart 
if overheated / overloaded 

5.2  Dimensions 

Overall size (HxWxD) 240 x 370 x 110mm 

Fixing centres 210 x 360mm 

PSU2007 

Clearances 75mm above, 20mm below, 50mm left & right 

Weight 3.2 Kg 

Overall size (HxWxD) 80 x 193 x 40mm 

Fixing centres 175mm 

CONTROL PANEL 

Cut-out size (HxW) 60 x 165mm 

Weight 170 g 

5.3  Approvals 

System: BSEN 1648-1, BSEN1648-2 compliant, BS7671: 2001 compliant 

Residual Current Device: RCD 40A 30mA trip to BS EN 61008 

Miniature Circuit Breakers: MCB’s (10 & 6A) type C 6000A breaking capacity to BSEN 60898 

Electro Magnetic Compatibility (EMC) directive 89/336/EEC 

Integrated Charger: BS EN 60335-1/2.29, 89/336/EEC, IEC61000-3.2/3:1995, EMC certificate 5172TC 3

rd

 party 

tested. 

5.4  Declaration of Conformity 

Equipment:

 Leisure Power Control System                      

Model name:

 PSU2007 / EC200 -STD / -DLX / -STD SW 

I hereby declare that the equipment named above has been designed to comply with the relevant sections of the 
above referenced approvals.  The unit complies with all essential requirements of the Directives. 
 

Signed: 

Name: 

Position: 

Manufacturer: 

 

 

Date: 

 

 

I L Sargent 

Technical Director 

Sargent Electrical Services 
Ltd 
Unit 39, Tokenspire 
Business Park 
Woodmansey 
Beverley 
East Yorkshire 
United Kingdom 

 

 

Summary of Contents for EC200

Page 1: ...t timer to control equipment in the absence of the user With the addition of an optional plug in remote control pack the Power and Auxiliary functions can be operated by a key fob controller The system meets relevant UK legislation including the requirements of BS7671 EN1648 1 and 2 Further technical data is contained in section 5 2 SYSTEM OVERVIEW The following diagram shows the components that m...

Page 2: ...s the requirements of BS7671 In most cases the site warden will hold information regarding suitability of supply If using a generator you also need to comply with the requirements instructions supplied with the generator B Switch the PSU2007 internal Charger unit OFF Locate the red Charger power switch on the PSU2007 and ensure the switch is in the OFF 0 position before connection to the mains sup...

Page 3: ...ames and sparks in the vicinity of the battery and do not smoke C Servicing Under normal circumstances it should not be necessary to remove the battery other than for routine inspection of the terminals and topping up of the battery fluid where applicable Please see instructions supplied with the battery Note Do not over discharge the battery One of the most common causes of battery failure is whe...

Page 4: ...necting lead at PSU2007 and behind Control Panel Contact your Dealer 12v Power turns off Battery save feature has operated to protect the Vehicle battery and the Leisure battery is flat see section 4 4 Engine has been started all equipment has been disconnected to meet EMC requirements Control Panel display corrupt erratic function Observe control panel handling instructions Reboot control panel b...

Page 5: ...ion 1 15 Amps Blue Slate Front Lights 2 15 Amps Blue Pink Rear Lights 3 10 Amps Red Yellow White 12v Sockets 4 10 Amps Red Black tracer Fans 5 5 Amps Tan Yellow Green Heater Hob Other Ignitions if fitted 6 5 Amps Tan Slate Red Aux Awning Light 7 10 Amps Red Green tracer Purple Water Pumps Toilet 8 20 Amps Yellow Charger internally connected Battery 20 Amps Yellow Brown Blue Fuse remotely located n...

Page 6: ...ry is selected and is indicated by the battery select LED off Pump ON OFF Use to turn the water pump s power on and off see section 4 3 The adjacent LED is illuminated when the pump power is ON Aux ON OFF Use to turn the Auxiliary power on and off see manufacturers handbook for detail of what items are operated by the auxiliary function The adjacent LED is illuminated when the auxiliary power is O...

Page 7: ...for details of the Vehicle Battery save feature 10 9 Poor 10 9 to 11 8 Fair 11 9 to 14 4 Good Fresh Water 25 Full Water level in the fresh water tank 5 measurement levels 0 Full Empty 25 Full 50 Full 75 Full 100 Full Waste Water 0 Full Water level in the waste water tank 2 measurement levels 0 Full 50 Full optional 100 Full External Temp 26 5 C External temperature in degrees centigrade as measure...

Page 8: ...E Use the up down buttons to change Press the select button to exit Please note the alarm uses a 24 hour cycle Alarm Off Shows the alarm clock status on off Press the select button to switch between OFF or ON The addition of a asterisk in the top left of the main display indicates that the alarm is set Set Event Timer Access to set the event timer Press the select button to select HOUR ON Use the ...

Page 9: ...mer is designed to allow the leisure vehicle user to turn the 12v power on or off same as using the control panel power button without being in the vehicle This allows lights or other equipment to be turned on or off at a predetermined time Example to turn on one interior light at 11 00pm Ensure the clock is set to the correct time Scroll to the Set Event Timer screen Following the instruction in ...

Page 10: ...heated overloaded 5 2 Dimensions Overall size HxWxD 240 x 370 x 110mm Fixing centres 210 x 360mm PSU2007 Clearances 75mm above 20mm below 50mm left right Weight 3 2 Kg Overall size HxWxD 80 x 193 x 40mm Fixing centres 175mm CONTROL PANEL Cut out size HxW 60 x 165mm Weight 170 g 5 3 Approvals System BSEN 1648 1 BSEN1648 2 compliant BS7671 2001 compliant Residual Current Device RCD 40A 30mA trip to ...

Page 11: ...Lights 12 Hob Ign 1 Front Lights 11 12v Sockets 10 Earth F Spare 9 Vehicle Batt E Toilet Pump 8 Leisure Batt D Rear Lights 7 Earth C Ext Pump 5 Leisure Batt A View looking into PSU Wire Colour Description Pin WHITE Fresh sensor 25 full 2 WHITE ORANGE Earth 8 RED YELLOW Engine running signal from alternator 7 PURPLE RED Waste sensor 100 full 6 Not in use by current customers Waste sensor 50 full 5 ...