1 Template
Instructions
<<Delete before
use>>
EC
60
0
EC600 Power Control System
Issue 2.3
Page 12 of 20
10
th
August 2017
Exit settings?
When timer 4 is completed the exit settings item is reached. Press
the select button to exit and save the settings.
The timer example above will set the heating to 22 degrees C and the hot water to boost at 7:30 in the
morning.
TRUMA Combi CP+
Menu Item
Description
Control
Set to MANUAL to use the controls supplied by the heating
appliance manufacturer
Set to TIMER to control the appliance by the control panel with the
settings below
Set to APP control the appliance by the Swift Command app
The following menu items are only available when in Timer control mode
Energy
Set the energy selection to GAS, MIX1, MIX2, EL1 or EL2. See the
heater user manual for a description of these settings.
Timer 1
Set the timer 1 event time
This setting adjusts in 15 minute increments
and uses the 24 hour clock
Example 07:30
T1 Heating
Set the timer 1 heating temperature
This setting can be off, or 5 through to 30
degrees C
Example 22 deg C
T1 H/Water
Set the timer 1 hot water temperature
This setting can be OFF, ECO or HOT
Example Eco
The menu now repeats for timer 2 through to timer 4
Exit settings?
When timer 4 is completed the exit settings item is reached. Press
the select button to exit and save the settings.
The timer example above will set the heating to 22 degrees C and the hot water to eco at 7:30 in the
morning.
WHALE
Menu Item
Description
Control
Set to MANUAL to use the controls supplied by the heating
appliance manufacturer
Set to TIMER to control the appliance by the control panel with the
settings below
Set to APP control the appliance by the Swift Command app
The following menu items are only available when in Timer control mode
WH Energy
Set the energy setting to OFF, GAS, EL1, EL2, MIX1 or MIX2. See
the water heater user manual for a description of these settings.
AH Energy
Set the energy setting to OFF, FAN, GAS, EL1, EL2 or EL3. See
the air heater user manual for a description of these settings.
Timer 1
Set the timer 1 event time
This setting adjusts in 15 minute increments
and uses the 24 hour clock
Example 07:30
T1 Heating
Set the timer 1 heating temperature
This setting can be off, or 5 through to 30
degrees C
Example 22 deg C
T1 H/Water
Set the timer 1 hot water temperature
Example On