background image

01/31/18

     17            1-800-810-WIRE • www.sargentlock.com • A8205B

Copyright © 2018, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

IN220 Exit Device

Secure chassis cover to chassis using (4) #8-32 x 5/16” oval head machine screws (Fig. 7).

7    Install Chassis Cover

Fig. 7

NOTE: Cable lengths exaggerated for illustrative purposes.

Summary of Contents for Sargent IN220

Page 1: ...Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited PoE Exit De...

Page 2: ......

Page 3: ...gain maximal ou inf rieur approuv pour l metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio lectrique l intention des autres utilisateurs il faut choisir le type d ant...

Page 4: ...lined architecture of Power over Ethernet PoE access control PoE enabled access control allows facilities to leverage existing network infrastructure for enhanced security and easier more cost effecti...

Page 5: ...ck plastic IN 220 EM01 B IPS W Reader assembly white plastic IN 220 EM01 B CP B Reader assembly FeliCa black plastic IN 220 EM01 B CP W Reader assembly FeliCa white plastic IN 220 EM01 B CP MB xxx Rea...

Page 6: ...le Styles 1 3 97 4152 Exit Trim ET With Cylinder 1 97 4153 Exit Trim ET Without Cylinder 68 7546 Motor Actuator Assembly 1 52 5657 Ecoflex ET Harness 1 4 68 7255 Chassis Assembly 1 68 7256 Chassis Ass...

Page 7: ...rence Catalog for Available Cylinders 1 2 Lever Reference Catalog for Available Styles 1 3 97 4136 Exit Trim ET With Cylinder 1 97 4137 Exit Trim ET Without Cylinder 68 7546 Motor Actuator Assembly 1...

Page 8: ...g Company is prohibited 01 31 18 IN220 Exit Device Installation Wiring 6 Overview SARGENT IN220 PoE Typical Application LMT Lock Management Tool A PoE frame harness assembly B PoE data hinge from McKi...

Page 9: ...for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Patch Panel Cable Cat 5e or higher 24 AWG RJ45 F Jack Approved Software Certified Integrator CI supplies and terminates...

Page 10: ...ength 24AWG Stranded Drain Wire for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Frame Harness Installation 1 Feed cut end of harness into hole on hinge side through si...

Page 11: ...t force and do not offset connectors Be sure they are completely seated flush Order of installation may vary Refer to appropriate sections for instructions 1 Prop door open 2 Using the ring terminal c...

Page 12: ...mended 3 Use appropriate templates IN220 template A8214 wood and metal Exit installation instructions A6770 Note Instruction examples show wood door installation For metal doors route cables inside do...

Page 13: ...oors have 3 4 raceway to the controller cutout Refer to template A8214 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push...

Page 14: ...nd two different sized ground lugs Fig 3A 1 Feed 6 pin connector and larger ground lug straight through to outside of door Fig 3A B while feeding smaller ground lug into wire hole up through wire chan...

Page 15: ...door surface A Connect motor harness adapter to chassis harness connector Fig 4A B For wood doors Route ET wire harness connector through the cylinder hole up and through the wire run channel to the...

Page 16: ...Chassis 4 10 Wood Screws or 10 24 Machine Screws Inside of Door 2 12 24 x 1 7 8 Flat Head Screws Through bolts Cylinder to Chassis Fig 6 For devices without cylinder go to Step 6 1 While installing t...

Page 17: ...y All rights reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited IN220 Exit Device Secure chassis cover to chassis using 4 8 32...

Page 18: ...ent Manufacturing Company is prohibited 01 31 18 IN220 Exit Device 8 Outside Reader and Mounting Plate Installation Fig 8A 1 Orient the reader so the LED lens is at the top 2 Feed the cable connector...

Page 19: ...ock Body Fig 9B Fig 9C 4 Next feed the cables connectors through the inside mounting assembly and gasket if required 5 Insert and partially tighten 2 through bolts prior to installation of connectors...

Page 20: ...Plate IMPORTANT Do not run wires through bottom hole in plate Fig 10A B it will damage wires and the controller connector Route wires around flange do not route wires through the flange hole Fig 10B C...

Page 21: ...gnment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate CAUTION To avoid possible damage to board to board c...

Page 22: ...ithout express written permission of Sargent Manufacturing Company is prohibited 01 31 18 IN220 Exit Device 12 Inside Cover Installation 1 Assemble cover by hooking top edge on inside mounting plate 2...

Page 23: ...ufacturing Company is prohibited IN220 Exit Device 1 Retrieve harness from end of rail Note Harness has limited travel and can be damaged 2 Attach harness to female connector on chassis 3 Install rail...

Page 24: ...1 If using a mullion install it prior to installing hardware 2 Doors should be pre prepped recommended 3 Use appropriate templates IN220 template A8215 Field Prep Template Exit installation instructio...

Page 25: ...have 3 4 raceway to the controller cutout Refer to template A8215 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push DPS...

Page 26: ...Fig 3A 1 Slide mortise lock into door and loosely secure with 2 flat head screws NOTE Exit chassis harness consists of a 6 pin female connector and two different sized ground lugs Fig 3A 2 Feed 6 pin...

Page 27: ...the cylinder hole up and through the wire run channel to the controller cutout For metal doors Route ET wire harness through the cylinder hole out the controller cutout C Pass top ET trim mounting pos...

Page 28: ...t chassis Note Be sure ET harness is clear of cylinder and tailpiece 2 Secure the cylinder by through bolting the cylinder through the exit chassis using 2 12 24 x 1 7 8 connecting screws see Fig 6A 3...

Page 29: ...y All rights reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited IN220 Exit Device Secure chassis cover to chassis using 4 8 32...

Page 30: ...ent Manufacturing Company is prohibited 01 31 18 IN220 Exit Device 8 Outside Reader and Mounting Plate Installation 1 Orient the reader so the LED lens is at the top 2 Feed the cable connector through...

Page 31: ...4 Next feed the cables connectors through the inside mounting assembly and gasket if required 5 Insert and partially tighten 2 through bolts prior to installation of connectors NOTE Cable lengths exa...

Page 32: ...ing Plate IMPORTANT Do not run wires through bottom hole in plate Fig 9A B it will damage wires and the controller connector Route wires around flange do not route wires through the flange hole Fig 9B...

Page 33: ...ignment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate CAUTION To avoid possible damage to board to board...

Page 34: ...on 1 Assemble cover by hooking top edge on inside mounting plate 2 Carefully press bottom of cover toward door without pinching wires 3 Secure the cover with the security allen wrench Inside Cover Ins...

Page 35: ...The key should extend and retract the deadbolt For units without a keypad add card using LCT software and test For units with a keypad add pin and card using LCT software and test 2 LED signaling Aft...

Page 36: ...uction institutional and industrial markets Copyright 2018 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written pe...