6–3
6–2
Specifications: Master Series
Model
AC 211S-00MS
AC 211P-00MS
AC 121S-00MS
Weighing range structure
SuperRange
PolyRange
SuperRange
Capacity/weighing range levels
g
210
60/120/210
120
Readability
g
0.0001
0.0001/0.0002/0.0005
0.0001
Tare range (by subtraction)
g
–210
–210
–120
Reproducibility (standard deviation)
g
≤
±0.0001
≤
±0.0001/0.0002/0.0005
≤
±0.0001
Linearity
g
≤
±0.0002
≤
±0.0002/0.0004/0.0005
≤
±0.0002
Response time (average)
s
–––––––––––––––––––––––––––––––––––––––––
≤
2.5 ––––––––––––––––––––––––––––––––––––––––
Shortest response time in the IQ-mode
s
–––––––––––––––––––––––––––––––––––––––––– 1.5 –––––––––––––––––––––––––––––––––––––––––
Adaptation to ambient conditions and application requirements
–––––––––––––––––––––––––– by selection of 1 of 4 optimized filter levels –––––––––––––––––––––––––
Display update (depends on the filter level selected)
s
––––––––––––––––––––––––––––––––––––––– 0.1– 0.4 –––––––––––––––––––––––––––––––––––––––
Sensitivity drift within 283–303 K
/K
–––––––––––––––––––––––––––––––––––––––
≤
±2·10
–6
–––––––––––––––––––––––––––––––––––––––
Ambient temperature range
K
–––––––––––––––––––––––– 283–303 (+10°C…+30°C; +50°F…+86°F) –––––––––––––––––––––––
Pan size
mm/in
––––––––––––––––––––––––––––––––––––– 90 Ø/3.5 Ø –––––––––––––––––––––––––––––––––––––
Weighing chamber (WxDxH)
mm/in
–––––––––––––––––––––––––––––– 200x180 x260/8x7.1x10.2 ––––––––––––––––––––––––––––––
Clearance above the weighing pan
mm/in
–––––––––––––––––––––––––––––––––––––––– 254/10––––––––––––––––––––––––––––––––––––––––
Net weight, approx.
kg/lb
––––––––––––––––––––––––––––––––––––––– 7.5/16.5 ––––––––––––––––––––––––––––––––––––––
AC power source/power requirements
V~
––––––––––––––––––––––––– via AC adapter, 230 or 115, +15%…–20% ––––––––––––––––––––––––
Frequency
Hz
–––––––––––––––––––––––––––––––––––––––– 48–60 ––––––––––––––––––––––––––––––––––––––––
Power consumption
VA
–––––––––––––––––––––––––––––––––– max.:16; average: 8 ––––––––––––––––––––––––––––––––––
Selectable weight units
––––––––––––– g, kg, ct, lb, oz, ozt, tlh, tls, tlt, gr, dwt, mg, /lb, tlc, mom, K, tol and bat ––––––––––––
Application programs
formulation; statistics; averaging; real-time clock with timer function for time-controlled measurements/
weighing; calculation of weights; totalling of weights; density determination; ID no. for
––– identification of data; mass unit conversion by toggling; tare memory; net total; weighing in percent;–––
over/under checkweighing; counting
Automatic zero tracking function (can be turned off by menu code)
–––––––––––––––––––––––––––––––––––– standard feature ––––––––––––––––––––––––––––––––––––
Built-in interface
––––––––––––––––––
RS-232C-S/V24-V28; 7-bit; parity: even, mark, odd, space;
––––––––
transmission rate: 150…19,200 baud;1 or 2 stop bits; software/hardware handshake
––––––––
Standard features/equipment supplied
Dust cover
x
x
x
Analytical draft shield chamber
x
x
x
AC adapter
x
x
x
Hanger for below-balance weighing
x
x
x
“isoCAL” self-calibration function
x
x
x
ISO/GLP-compliant record/printout
x
x
x
Numeric keypad
x
x
x
▲
▲▲▲▲▲
▲▲▲▲▲▲▲
▲
▲
▲
▲▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲