Safety Inspection

If there is any indication that safe operation of the
balance/scale with the AC adapter is no longer 
warranted:

§

Turn off the power and disconnect the equipment
from AC power immediately

> Lock the equipment in a secure place to ensure that

it cannot be used for the time being

Safe operation of the balance/scale with the AC
adapter is no longer ensured when:

– there is visible damage to the AC adapter

– the AC adapter no longer functions properly

– The AC adapter has been stored for a relatively long

period under unfavorable conditions

In this case, notify your nearest Sartorius Service
Center or the International Technical Support Unit
based in Goettingen, Germany.  Maintenance and
repair work may only be performed by service tech-
nicians who are authorized by Sartorius and who

– have access to the required maintenance manuals

– have attended the relevant service training 

courses

Instructions for Recycling the Packaging

To ensure adequate protection for safe shipment,
your balance/scale has been packaged to the extent
necessary using environmentally friendly materials.
After successful installation of the balance/scale,
you should return this packaging for recycling
because it is a valuable source of secondary raw
material. 
For information on recycling options, including 
recycling of old weighing equipment, contact your
municipal waste disposal center or local recycling
depot.

Summary of Contents for Basic lite

Page 1: ...98648 008 55 Operating Instructions Sartorius Basiclite Sartorius Gemlite Electronic Precision Balances and Precious Metal Scales...

Page 2: ...t Total Formulation Second Tare Memory 17 Toggle Between Weighing Units Configuring the Balance Scale 18 Setting the Parameters Menu Codes 19 Balance Scale Operating Menu Overview 20 Error Codes 21 Ca...

Page 3: ...chapter entitled Care and Maintenance under the section on Safety Inspection Save the box and all parts of the packaging until you have successfully installed your balance scale Only the original pac...

Page 4: ...air can condense on the surfaces of a cold balance scale whenever it is brought into a substantially warmer place If you transfer the balance scale to a warmer area make sure to condition it for abou...

Page 5: ...r in the order given Draft shield base place it on the balance scale so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan...

Page 6: ...GM2202 GM1202 A non rechargeable or rechargeable battery is not included with the equipment supplied Use only a commercially available non rechargeable or rechargeable 9 volt battery When using a rech...

Page 7: ...ce scale any time you set it up in a new location Use only the 2 front feet of the balance scale for leveling Turn the 2 rear feet until they are in position only on models BL1500S and GM1502 GM2202 a...

Page 8: ...ale To load factory set configurations See Configuring the Balance Scale parameter 9 1 To tare the balance scale Press t Additional Functions To turn off the balance scale Press e Example Basic weighi...

Page 9: ...1 4 1 Example Calibrate the balance scale Menu code settings Factory set codes Step Key or instruction Display Printout 1 Turn on the balance scale e 2 Tare the balance scale t 0 0 g 3 Begin calibrat...

Page 10: ...Scale The average piece weight is automatically output via the optional data interface port after ini tialization if the menu code for Printout with data ID codes is set Press v to toggle the display...

Page 11: ...he balance scale t 0 0 g 13 Display the reference sample v 2 sec ref 20 briefly quantity here 20 pcs 14 Place the reference sample 66 0 g quantity 20 pcs on the balance scale here 66 g 15 Start the ap...

Page 12: ...alance Scale The reference percentage is automatically output via the optional data interface port after ini tialization if the menu code for Printout with data ID codes is set Press v to toggle the d...

Page 13: ...cale e 12 Tare the balance scale t 0 0 g 13 Display the reference percentage v 2 sec ref 100 14 Place the reference weight 222 5 g for 100 on the balance scale here 222 5 g 15 Start application if the...

Page 14: ...culated value You can set the number of subweighing operations performed in the operating menu See Configuring the Balance Scale Press v for at least 2 sec to display the preset number of subweighing...

Page 15: ...ntout 1 Turn on the balance scale e 2 Tare the balance scale t 0 0 g 3 Display the number of subweighs here 10 v 2 sec ref 10 briefly 4 Place sample on the balance 8888 scale weight readout fluctuates...

Page 16: ...ion Display Printout 1 Turn on the balance scale e 2 Place an empty container on 65 0 g the balance scale 3 Tare the balance scale t 4 Add the first component 120 5 g 5 Store the first component weigh...

Page 17: ...zt 1 7 8 3 1 8 Hong Kong taels 0 02671725000 tlh 1 7 9 3 1 9 Singapore taels 0 02645544638 tls 1 7 10 3 1 10 Taiwanese taels 0 02666666000 tlt 1 7 11 3 1 11 Grains 15 43235835000 GN 1 7 12 3 1 12 Penn...

Page 18: ...ments are displayed t briefly 1 To navigate within a menu t 2 level the last menu option is repeatedly followed by the first option 9 1 3 Select the 2nd menu level p 1 1 4 Select the 3rd menu level p...

Page 19: ...description 3 Application 3 1 Weight unit 2 see Toggle between Weight Units parameters 3 2 Display accuracy 3 2 1 Standard resolution 3 2 3 Increased resolution 3 3 Reference qty or see the desired a...

Page 20: ...tare the balance scale balance scale is loaded Unload the balance scale e 09 When gross value zero no tare Tare the balance scale e 10 The t key is blocked when Press c to clear the there is data in t...

Page 21: ...ained persons to perform repairs may lead to hazards for the user Cleaning Disconnect the balance scale from the AC adapter and unplug any interface cables that are connected to the balance scale Make...

Page 22: ...vice Center or the International Technical Support Unit based in Goettingen Germany Maintenance and repair work may only be performed by service tech nicians who are authorized by Sartorius and who ha...

Page 23: ...selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 1 0 4 External calibration weight g 200 E2 100 E2 50 E2 of at least accuracy class lb 0 4 0 2 0 1 Ne...

Page 24: ...evels Display update depends on the filter level selected s 0 2 0 4 0 2 0 4 0 2 0 8 External calibration weight g 100 F1 20 F1 1000 F2 of at least accuracy class lb Net weight approx kg lb 2 8 6 2 2 8...

Page 25: ...selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight g 100 F1 2000 F1 1000 F1 1000 F1 500 F2 of at least accuracy class...

Page 26: ...1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight g 100 F2 100 F2 100 M1 5000 F2 of at least accuracy class lb 0 2 0 2 10 Net we...

Page 27: ...tion to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight kg 1 F2 1 M1 0 5 M1 5 M1 5 M1 1 M1 o...

Page 28: ...e required Carrying case for models with a readability 1mg YDB01BL for models BL210S BL120S BL60S YDB02BL Product Order No Dust cover for use during weighing for models with a rectangular weighing pan...

Page 29: ...29 C...

Page 30: ...t the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the right to mak...

Reviews: