background image

26

Accessories (Options)

Product

Order No.

Interface port, installation kit

for models with a
readability  1mg

YDO01BL

for models BL210S, BL120S, 
BL60S, GC503

YDO02BL

Data printer

YDP04

Data printer

YDP03-0CE

with date/ time, statistics
evaluation and transaction 
counter functions and LCD 
(data interface required)

Paper (5 rolls)

6906937

Remote display 
(data interface required)

reflective

YRD12Z

for overhead projectors, 
transmissive 

YRD13Z

External rechargeable battery pack YRB08Z
with external battery charger
(hours of operation: 20 or 40.
depending on balance/ scale model)

SartoWedge data transfer software YSW01
for on-line storage of weighing data

Interface cable

7357312

for connecting a PC; 25-pin

Universal remote control switch:
(data interface required)
Foot switch with T-connector

YFS01

Hand switch with T-connector

YHS01

T-connector

YTC01

for connecting 2 peripheral
devices
(data interface required)

Carrying case

for models with a
readability  1mg

YDB01BL

for models BL210S, BL120S, 
BL60S

YDB02BL

Product

Order No.

Dust cover, for use during weighing

 for models with a rectangular 

weighing pan

6960BC02

for models with a round 
weighing pan 

6960BC03

Attaching the dust cover to models 
with a glass draft shield:

Remove adhesive strip from 
balance/ scale housing
Place dust cover on balance/ scale
Stick adhesive strip on dust cover

Gem trays

300 ml, weight: 86 g,
stainless steel 

6407

1000 ml, wt.: 240 g, 
stainless steel

641211

300 ml, wt.: 22 g, aluminum

69641304

110 ml, 90   mm, aluminum

YWP02G

270 ml, wt.: 62 g,
137   mm stainless steel

YWP03G

Calibration weights

for BL210S (200 g; E2)

YCW5228

for BL120S, BL150S, 
GC503*  (100 g; E2)

YCW5128

for BL60S (50 g; E2)

YCW4528

for the BL150, BL310, GM512,
GM212, GM312 (100 g; F2)

YCW5148

for the BL610, BL600, GM612,
GM601, (500 g; F2)

YCW5548

for the BL1500S, GM1502
(1 kg; F1)

YCW6138

for the BL1500, BL3100, BL3,
GM3101, GM1205 (1 kg; F2) YCW6148
for the BL6100, BL6, BL12,
GM6101 (5 kg; F1)

YCW6538

or alternative

YSS653-00

*  = F1 100-g weight supplied 

with the GC503 scale

Summary of Contents for BL310

Page 1: ...INSTRUCTION MANUAL Balance Model BL310 Brand...

Page 2: ...SartoriusBasiclite Series SartoriusGemlite Series Electronic Precision Balances and Precious Metal Scales Operating Instructions 98648 008 55...

Page 3: ...otal Formulation Second T are Memory 16 T oggle Between Weighing Units 17 Configuring the Balance Scale Setting the P arameters Menu Codes 18 Balance Scale Operating Menu Overview 19 Error Codes 20 C...

Page 4: ...chapter entitled Care and Maintenance under the section on Safety Inspection Save the box and all parts of the packaging until you have successfully installed your balance scale Only the original pac...

Page 5: ...e air can condense on the surfaces of a cold balance scale whenever it is brought into a substantially warmer place If you transfer the balance scale to a warmer area make sure to condition it for abo...

Page 6: ...chamber in the order given Draft shield base place it on the balance so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan...

Page 7: ...M1502 A non rechargeable or rechargeable battery is not included with the equipment supplied Use only a commercially available non rechargeable or rechargeable 9 volt battery W hen using a rechargeabl...

Page 8: ...ce scale any time you set it up in a new location Use only the 2 front feet of the balance scale for leveling T urn the 2 rear feet until they are in position only on models BL 1500S and GM1502 T urn...

Page 9: ...le T o load factory set configurations See Configuring the Balance Scale parameter 9 1 T o tare the balance scale Press t Additional Functions T o turn off the balance scale Press e Example Basic weig...

Page 10: ...1 4 1 Example Calibrate the balance scale Menu code settings Factory set codes Step Key or instruction Display Printout 1 T urn on the balance scale e 2 T are the balance scale t 0 0 g 3 Begin calibra...

Page 11: ...Scale The average piece weight is automatically output via the optional data interface port after initialization if the menu code for Printout with data ID codes is set Press v to toggle the display b...

Page 12: ...he balance scale t 0 0 g 13 Display the reference sample v 2 sec r ef 20 briefly quantity here 20 pcs 14 Place the reference sample 66 0 g quantity 20 pcs on the balance scale here 66 g 15 Start the a...

Page 13: ...lance Scale The reference percentage is automatically output via the optional data interface port after initialization if the menu code for Printout with data ID codes is set Press v to toggle the dis...

Page 14: ...ale e 12 T are the balance scale t 0 0 g 13 Display the reference percentage v 2 sec r ef 100 14 Place the reference weight 222 50 g for 100 on the balance scale here 222 5 g 15 Start application if t...

Page 15: ...culated value Y ou can set the number of subweighing operations performed in the operating menu See Configuring the Balance Scale Press v for at least 2 sec to display the preset number of subweighing...

Page 16: ...out 1 T urn on the balance scale e 2 T are the balance scale t 0 0 g 3 Display the number of subweighs here 10 v 2 sec r ef 10 briefly 4 Place sample on the balance 8888 scale weight readout fluctuate...

Page 17: ...ction Display Printout 1 T urn on the balance scale e 2 Place an empty container on 65 0 g the balance scale 3 T are the balance scale t 4 Add the first component 120 5 g 5 Store the first component w...

Page 18: ...ozt 1 7 8 3 1 8 Hong Kong taels 0 02671725000 tlh 1 7 9 3 1 9 Singapore taels 0 02645544638 tls 1 7 10 3 1 10 T aiwanese taels 0 02666666000 tlt 1 7 11 3 1 11 Grains 15 43235835000 GN 1 7 12 3 1 12 Pe...

Page 19: ...ments are displayed t briefly 1 T o navigate within a menu t 2 level the last menu option is repeatedly followed by the first option 9 1 3 Select the 2nd menu level p 1 1 4 Select the 3rd menu level p...

Page 20: ...am programs description 3 Application 3 1 Weight unit 2 see T oggle between Weight Units parameters 3 3 R eference qty or see the desired application program description 5 through 7 appliesonly if an...

Page 21: ...tare the balance scale balance scale isloaded Unload the balance scale e 09 W hen gross value zero no tare T are the balance scale e 10 The t key is blocked when P ress c to clear the there is data in...

Page 22: ...ined persons to perform repairs may lead to hazards for the user Cleaning Disconnect the balance scale from the AC adapter and unplug any interface cables that are connected to the balance scale Make...

Page 23: ...vice Center or the International T echnical Support Unit based in Goettingen Germany Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius and who ha...

Page 24: ...nds on the filter level selected s 0 1 0 4 External calibration weight g 200 E2 100 E2 50 E2 100 F1 1000 F2 of at least accuracy class lb 0 4 E2 0 2 E2 0 1 E2 Net weight approx kg lb 3 0 6 6 3 0 6 6 3...

Page 25: ...selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight g 100 F 1 1000 F 1 500 F2 100 F2 100 F2 100 M1 5000 F2 of at least...

Page 26: ...n to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight kg 1 F2 1 M1 0 5 M1 5 M1 5 M1 1 M1 of a...

Page 27: ...e required Carrying case for modelswith a readability 1mg YDB01BL for modelsBL 210S BL 120S BL 60S YDB02BL Product Order No Dust cover for use during weighing for models with a rectangular weighing pa...

Page 28: ...rtorius and must check and if necessary correct these modifications and connections On request Sartorius will provide information on the minimum operating specifications in accordance with the Standar...

Page 29: ...rm or by any means without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG...

Reviews: