Getting Started
Storage and Shipping Conditions
– Do not expose the scale to extreme
temperatures, jolts, impacts, vibration
or moisture.
Unpacking the Scale
●
After unpacking the scale, check it
immediately for any visible damage as
a result of rough handling during
shipment.
$
If any damage is visible, proceed as
directed in the chapter entitled “Care
and Maintenance,” under the section
on “Safety Inspection.”
It is a good idea to save the box and
all parts of the packaging until you have
successfully installed your scale. Only
the original packaging provides the best
protection for shipment. Before packing
your scale, unplug all connected cables
to prevent damage.
Important Note Concerning Verified
Scales Approved for Use as Legal
Measuring Instruments in the EU*:
Provided that an official seal is required
for the verified scale, a control seal is
affixed to the scale. This seal will be
irreparably damaged if you attempt
remove it. If the seal is broken, the
validity of the verification will become
void and you must have your scale
re-verified.
* including the Signatories of the Agree-
ment on the European Economic Area
Equipment Supplied
The equipment supplied includes the
components listed below:
FC06BBE-S
– Complete scale with data interface port
– AC adapter
– Column for display and control unit
– Retainer
– Dust cover
– Shield ring
– Load plate support
– Load plate
– Glass cylinder/draft shield
– Draft shield cover
FC6CCE-H, FC2CCE-S
– Complete scale with data interface port
– AC adapter
– Column for display and control unit
– Retainer
– Dust cover
– Load plate shield
– Load plate
FC12CCE-S, FC6CCE-S
– Complete scale with data interface port
– AC adapter
– Column for display and control unit
– Retainer
– Dust cover
– Load plate
FCG34EDE-H, FCG34EDE-P,
FCG16EDE-H, FCG12EDE-P,
FCG64EDE-S, FCG64EDE-H
– Complete scale with data interface port
– AC adapter
– Column for display and control unit
– Retainer
– Load plate
Installation Instructions
When choosing a location to set up
your scale, observe the following so
that you will be able to work with
added speed and accuracy:
– Avoid placing the scale in close prox-
imity to a heater or otherwise exposing
the scale to heat or direct sunlight
– Protect the scale from drafts hat come
from open windows or doors
– Do not expose the scale to extreme
moisture over long periods
– Avoid exposing the scale to extreme
vibrations during weighing
– Set up the scale on a stable, even
surface
– Protect the scale from aggressive
chemical vapors
Conditioning the Scale
Moisture in the air can condense on
the surfaces of a cold scale whenever it
is brought into a substantially warmer
place. If you transfer the scale to a
warmer area, make sure to condition it
for about 2 hours at room temperature,
leaving it unplugged from AC power.
7