background image

Summary of Contents for IS 64 FEG-S0CE

Page 1: ...PRESENTED BY JPBOWLIN COM 817 332 8116 J P Bowlin is a quality driven Calibration Company that has provided calibration repair and sales of all types of weighing and measurement products since 1931 ...

Page 2: ...Sartorius IS 64 FEG S0CE Weighing Platform Installation and Operating Instructions 98648 004 76 ...

Page 3: ... the Weighing Platform 9 Instrument 27 Connecting the Weighing Platform 10 Separate Testing and Verification of the Separate Power Connection Optional 10 Individual Weighing Instrument Components 27 Safety Precautions 12 Effect of the Preload on the Acceptability for Warm up Time 13 Verification in the EU 28 Type Approval Certificate 30 Operating Limits 14 Certificate on Testing by the PTB 31 Maxi...

Page 4: ...gnation 1 Load plate 2 Manufacturer s label for a weighing platform verifiable or verified as a legal measuring instrument 3 Leveling feet 4 Level indicator 5 Connecting cable interface port power supply 6 Blank for power supply cable gland optional ...

Page 5: ...esigned to ensure that the weighing platform will not be damaged even it is dropped from a height of 80 cm approx 32 inches After unpacking the weighing platform please check it immediately for any visible damage lf you detect any damage proceed as directed in the section entitled Safety Inspection It is a good idea to save the box and all parts of the packaging until you have successfully install...

Page 6: ...tarted lf you operate the weighing platform in a Zone 2 hazardous area outside the Federal Republic of Germany you must comply with the national electrical code and applicable safety regulations of your country For information on the currently valid regulations applicable in your country please ask your local Sartorius Service technician office or dealer The weighing platform may not be operated i...

Page 7: ...ing of angular braces around the weighing platform To calculate the dimensions for this protective frame refer to the section entitled Dimensions Scale Drawings Conditioning the Weighing Platform Do not expose the weighing platform to extreme moisture over long periods Moisture in the air can condense on the surfaces of a cold platform whenever it is brought to a substantially warmer place lf you ...

Page 8: ...ter approx 3 ft The IP67 protection of the weighing platform is ensured only under the following conditions The weighing platform is maintained in original factory condition The rubber seals of the weighing cell and the A D Converter are not perforated All cables are securely fastened in place by cable glands The service switch aperture is closed and secured with a cover and a sealing ring Both th...

Page 9: ...e retainer plates using the Allen wrench key that is supplied with the weighing platform Slide the retainer plates in the direction of the arrows Afterwards retighten the retainer plates so that they are not in contact with the pins Use the Allen wrench key to remove screw no 1 and loosen screw no 2 Turn the red color coded transport locking device by 90 in the direction of the arrow and refasten ...

Page 10: ...at the 3 leveling feet touch the surface The leveling feet must equally support the weight of the platform After leveling the weighing platform retighten the locknuts securely against the platform frame Installing the Weighing Platform in a Pit The level indicator can be detached To find out how contact your local Sartorius dealer or service technician Before operating the scale connect the follow...

Page 11: ...parate power supply unit there are a few restrictions that apply to the cable lengths between these components lf you use a cable that is longer than 12 meters 40 feet between the weighing platform and the Sartorius isi industrial terminal each of these components must be energized by a separate AC adapter Separate Power Connection Optional for the Weighing Platform Have your local Sartorius deale...

Page 12: ...n external industrial grade AC adapter Make sure that the voltage rating printed on this unit is identical to your local line voltage lf the voltage specified on the label or the plug design does not match the rating or Standard you use please contact your local Sartorius dealer or office To use a main feeder cable from the ceiling or to mount a CEE plug you will have to make arrangements inside y...

Page 13: ...puter with adequate protection so that the cable cannot get damaged Fixed Power Connection If the power cable is permanently installed or secured so that it cannot be unplugged the weighing platform must be able to be switched off by a suitable emergency switch This emergency switch must be installed near the weighing platform and be within easy reach In addition this switch must be labeled as an ...

Page 14: ...of the Agreement on the European Economic Area Preparing the Weighing Platform for Verification as a Legal Measuring Instrument in the EU After initially connecting the weighing platform to the power supply or after a relatively long power outage allow the platform to warm up for at least 24 hours The menu access switch must be unlocked and the correct configuration selected by menu code for speci...

Page 15: ... overload capacity of this IS model is 130 kg Shock Resistance Even though Sartorius weighing platforms feature a highly rugged construction there are some limits Avoid dropping heavy objects from a considerable height on the weighing platform and do not expose it to strong side impact Sartorius weighing platforms withstand shock according to the shock response spectrum defined in the IEC68 Standa...

Page 16: ...h the load plate lf you install the weighing platform in conveyor Systems in Zone 2 hazardous areas you must comply with the applicable safety regulations e g in Germany with VDE0165 Special precautions must be taken to prevent the build up of static electricity caused by moving parts e g roller conveyors Preload Range Zero Setting Range The weight of components that are securely installed on the ...

Page 17: ...igh resolution i e the weighing range is subdivided into more than 64 000 digits There is one level of readability for the entire weighing range e g 1 g SingleRange The weighing range is subdivided into 64 000 intervals digits maximum There is one level of readability for the entire weighing range e g 10 g Multi interval Weighing ranges with multiple levels of accuracy The Multi interval function ...

Page 18: ... 2 kg 1 28 1 02 0 62 0 32 1 28 1 28 1 28 0 62 0 32 Initial zero setting range kg 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 Preload 1 kg 0 13 33 48 0 0 0 33 48 ISO test function 2 yes yes yes yes yes yes yes yes yes Metrological specifications Accuracy class Minimum capacity Min acc to CD 3 g 50 50 100 200 400 200 100 Verification scale interval g 10 10 5 10 20 10 20 10 5 Temperature range o C 0 40 0 40 ...

Page 19: ...ler or Sartorius service technician only Frequency Hz 48 63 Power consumption with isi 10 20 30 connected to ING2 platform connected only to ING2 VA approx VA 34 maximum 18 average 11 average Selectable weights units g kg ct oz ozt tlh tls tlt GN dwt mg lb tlc mom K tol bat MS tons the weight unit kg can only be selected for use in legal metrology e g legal for trade applications Automatic zero tr...

Page 20: ...19 ...

Page 21: ...20 Area for attaching conveyor components fasteners may protrude below by 10 mm max Dimensions Scale Drawings IS 64 FEG S0CE All dimensions are given in millimeters ...

Page 22: ...ed E Signal GND F Menu Access Switch for Calibration Adjustment routed externally G VCC 24 V Power Supply H Not Connected J GND 24 V Power Supply K GND 24 V Power Supply L RxD TxD P M VCC 24 V Power Supply Interface Connector Recommended TvpeC091D 12 pin Amphenol IP67 Type of cable AWG 24 specification Be sure to follow the instructions given for connecting the weighing platform to the power suppl...

Page 23: ...02 One of the requirements for For example re adjust recalibrate calibration adjustment has not the weighing platform only when a been met e g the weighing zero readout is displayed on the platform is still loaded terminal Zero the weighing platform Unload the weighing platform The weight display briefly indicates Err 03 Calibration adjustment was Allow the equipment to warm up unable to be comple...

Page 24: ...ect a available is too low because the different configuration code relatively high preload setting has reduced the maximum capacity The special code remains displayed None of the keys has been pressed Press any key since the weighing platform was switched on The weight readout changes constantly instable environment ambient Set up the weighing platform in a conditions e g too much Vibration diffe...

Page 25: ...n tested according to EN 60529 and found to comply with the IP67 protection Standard will remain leaktight for a maximum of 30 minutes if immersed at a maximum depth of 1 meter approx 3 ft However pressurized water e g strong jets of water using a hose or high pressure cleaning equipment is not allowed to clean the IP67 protected weighing platform To clean the weighing platform exposed to a corros...

Page 26: ...e power supply is no longer ensured when there is visible damage to the power supply the power supply no longer functions properly the power supply has been stored for a relatively long period under adverse conditions In this case notify your nearest Sartorius Service Center or the International Technical Support Unit based in Goettingen Germany Only service technicians who are authorized by Sarto...

Page 27: ...Sartorius isi industrial terminal 1 to 3 weighing platforms or a Sartorius isi industrial terminal 1 weighing platform up to 2 further EC or nationally type approved weighing instruments As a weighing instrument the weighing platform is not allowed to be used for weighing goods intended for direct sale to the public Since the platform s type approval certificate for verification applies to non aut...

Page 28: ... must change the preload setting before verification only The legal basis permitting Sartorius to perform initial verification is constituted by the following 1 EC Council Directive no 2009 23 EC on non automatic weighing instruments which has been applicable within the harmonized Infernal Market of the European Union since 1 January 1993 and 2 the certificate issued by the Metrology Department Ei...

Page 29: ...by independently issued certificates or reports provided by a Notified Body in the EU and the Signatories of the Agreement on the European Economic Area For applications not subject to the regulations of legal metrology any type of auxiliary device can be connected to the weighing platform D A Converter Model YDA01 Z Sartorius Additional printer bar code Scanner remote display modern PC device for...

Page 30: ......

Page 31: ......

Page 32: ...y years of trouble free service The mark may be affixed only to weighing instruments and associated equipment that comply with the applicable Directive s Council Directive 89 336 EEC Electromagnetic Compatibility EMC This Directive regulates the use of equipment that can cause electromagnetic interference or whose functioning can be influenced by such interference Applicable European Standards Lim...

Page 33: ...rmity for weighing instruments that have been verified by Sartorius for use as legal measuring instruments and that have an EC Type Approval Certificate see page 33 or next page The legal basis allowing Sartorius to perform EC verification is constituted by the EC Council Directive No 2009 23 EC on non automatic weighing instruments that has been in effect since January 1 1993 in the Infernal Mark...

Page 34: ......

Page 35: ...ich will guarantee you optimal results in working with your weighing instrument Installation Startup Inspection Training Initial verification lf you would like Sartorius to perform initial verification of your weighing instrument contact an authorized service representative Subsequent Verifications within the European Countries The validity of the verification will become void in accordance with t...

Page 36: ... YD0531S Extension cable to connect an isi terminal to a weighing platform 1 2 pin round connector to 2 contact round connector IP65 6 m YCC 01 ISM6 Round female connector IP65 69 QC0011 type C091 D 1 2 contact Amphenol for configuring own cable Round male connector IP65 69 QC0010 type C091 D 1 2 pin Amphenol for configuring own cable Adapter cable from round connector to PC YCC 01 0017D2 25 pin D...

Page 37: ...d by an authorized service technician only YAS031S required for 220 V 6971899 for 11O V 6971500 Adapter cable for connecting the weighing YRB 01 IS platform to a 1 2 V car battery or to a separate 12 V power source using the terminal leads cable length 3 7 long 12 ft with integrated switch and fuse reverse battery polarity protection to be installed using the YAS031S by an authorized Service techn...

Page 38: ......

Page 39: ......

Page 40: ......

Page 41: ... TN Pro model C Combics Pro type i isi10 isi20 isi30 type Y YAC01LA type Y YAC01LP type Y YAC01FC type Y YAC02FC PC with S Sartorius Win Scale software EC Type Approval Certificate No D D97 09 018 type i iso TEST is applicable ID plate for class configurations ID plate for class configurations Select and Attach Plate Containing Metrological Data Plates with the metrological data Max Min e and d mu...

Page 42: ......

Page 43: ......

Page 44: ......

Page 45: ...n any form or by any means without the prior written permission of Sartorius The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the right to make changes to the technology features specifications and design of the equipment without notice Status June 2011 Sartorius Göttingen Germany Printed in Germany been bleach...

Reviews: