Application: Totalizing
L
With the Totalizing application, you
can add weight values together in the
totalizing memory. In addition to
weight values, the number of individual
values added to memory is also saved
(transaction counter).
Features
– Totalize up to 999 individual weights
Save values automatically:
– Save both net values and calculated
values (if available). Configuration:
Appl
L
:
3.16.
– Save weight values and calculated
values from Counting, Weighing
in Percent or Checkweighing.
Configuration:
Appl
L
:
3.22.
– Current transaction number displayed
in the text line (indicating the items
already added)
– Weighing in up to a defined target,
with the totalization memory content
+ current weight displayed in the
text line.
– Save weight values manually or
automatically
– Activate info-mode by pressing
I
– Automatic printout when value saved
– Automatic taring of container weight.
Configuration:
Appl
L
:
3.7.
– Content of totalizing memory stored
in battery-backed (non-volatile) memory
when the Midrics 2 is switched off.
– Closing application program; deleting
parameters:
The value for reference sample weight
remains active in the reference memory
until you delete it by pressing the
c
key, overwrite it or until you select
a different application.
– Restore factory settings:
Appl
L
:
9.1.
The Midrics has a totalizing memory for
adding individual net and gross values.
You can save weight values in totalizing
memory manually or automatically.
Configuration:
Appl
L
:
3.16.
– Add a weight value manually by
pressing
O
The net value from the active platform
is added to the value already saved in
totalization memory and the transaction
counter value is increased by one.
When a value is added manually, the
program does not check whether
the platform has been unloaded since
the last time the
O
key was pressed.
– Value saved automatically when
the weighing platform is stable and the
defined minimum load is exceeded.
If the defined minimum load is not
exceeded, you can save the item
manually by pressing the
O
key.
The scale must be unloaded before
the sample is placed on the platform.
The weighing platform is considered
to be unloaded when the load is less
than 50% of the minimum load.
The number of items added to memory
is displayed in the text line.
Press the
c
key to clear the totalizing
memory. A printout is generated
automatically.
– Tare function:
1) If you store a tare (weight value) by
pressing the
)
key, you can later
enter a tare value manually. The tare
value you enter is added to the stored
tare value.
Setting: menu code 3.25.1
(factory default)
2) A tare value entered manually
overwrites a stored tare value (weight
value). If you enter a tare value manu-
ally, a tare value (weight value) stored
later overwrites the manually entered
value.
Setting: menu code 3.25.2
Operating menu setting:
Appl
L
:
3.25
Preparation
§
Switch on the scale: Press
e
§
While all segments are lit,
press the
)
key
§
Select the Application menu:
Press
k
repeatedly until
APPL
is displayed
§
Open the Application menu:
Press the
)
key
§
Select the Totalizing application:
Press the
k
key repeatedly until
the desired menu item is displayed
and press
)
to open the submenu
76
Summary of Contents for Midrics 1
Page 1: ...Operating Instructions Sartorius Midrics 1 Midrics 2 Models MIS1 MIS2 Indicators 98648 014 89 ...
Page 92: ...92 Dimensions Scale Drawings All dimensions given in millimeters 92 ...
Page 97: ...97 C ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...100 ...
Page 101: ...101 ...
Page 102: ...102 ...
Page 104: ...104 ...