Warnings and Safety Precautions

This scale meets the guidelines and stan-
dards governing electronic equipment,
electromagnetic compatibility and the
stipulated safety standards. Improper use
or handling can result in property dam-
age and/or personal injury. To prevent
damage to the equipment, read these
operating instructions 
thoroughly before using your scale. Keep
these instructions in a safe place.

– Do not expose the scale to extreme tem-

peratures, aggressive chemical vapors,
moisture, shocks and vibrations

– The display values can be impacted when

subjected to extreme electromagnetic
influence. When the negative influence
has subsided, the scale will again be fully
operational. 

– The equipment must be used indoors 
– The scale may not be operated in 

hazardous/ EX Zone areas

– To ensure safety, disconnect the equip-

ment from power before connecting or
disconnecting the cables or electronic
peripheral devices 

– If you use cables purchased from 

another manufacturer, check the pin
assignments in the cable against those
specified by Sartorius before connecting
the cable to Sartorius equipment, and
disconnect any wires that are assigned
differently. The operator shall be solely
responsible for any damage or injuries
that occur when using cables not 
supplied by Sartorius.

– When connecting the scale to the power

supply, the laws valid in your country
must be observed. If you should have any
questions, please contact your supplier or
Sartorius Customer Service for informa-
tion on the legal regulations applicable in
your country. The scale must be installed
by a certified technician to avoid forfei-
ture of all claims under the manufacturer’s
warranty.

– If you see any indication that the scale

cannot be operated safely (for example,
due to damage), turn it off and lock it in
a secure place or otherwise prevent use of
the equipment for the time being. Adhere
to the accident prevention regulations
and inform the operators, accordingly. 

– Always make sure the equipment is 

disconnected from AC power before
performing any installation, cleaning,
maintenance or repair work on the scale.
To avoid forfeiture of all claims under the
manufacturer’s warranty, all repair and
maintenance work must be performed by
authorized Sartorius service technicians.

– All other cables connecting the weighing

equipment and peripheral devices, as well
as the wiring inside the devices, are cased
in PVC materials. Chemicals that corrode
these materials must be kept away from
these cables.

– Never use a hammer to close the lid of a

paint can while it is still on the weighing
pan. Otherwise, you will damage the
weighing system.

Summary of Contents for PMA 7501-000G

Page 1: ...98648 015 03 Installation Instructions Sartorius PMA World PMA Net Model PMA 7501 000G PMA 7501 000GL Electronic Paint mixing Scales...

Page 2: ...paint mixing applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Graphic display 11 Weighing pan 12 Interfaces D Sub plug 9...

Page 3: ...in stand alone mode or using the application software e g paint manu facturers paint mixing applications installed on your PC Communication is carried out via the data interface If required Sartorius...

Page 4: ...amage or injuries that occur when using cables not supplied by Sartorius When connecting the scale to the power supply the laws valid in your country must be observed If you should have any questions...

Page 5: ...d Scale Weighing pan AC adapter or power supply 2 protective plugs in the column Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibra tion...

Page 6: ...ng or if the plug design differs from your local standard contact your Sartorius office or dealer Use only gen uine Sartorius AC adapters The use of AC adapters from other manufacturers even if these...

Page 7: ...omponents until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan...

Page 8: ...symbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you zero the displa...

Page 9: ...ortant Note The flashing arrow n on the display means that the weight value shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula t...

Page 10: ...the S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you already poured in This mod...

Page 11: ...the y key 4 several times to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 7 g 12 Pour in paint until 0 0 g is displayed 0 0 g 13 Press th...

Page 12: ...onnection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key Center the calibration...

Page 13: ...e RS keys to select the desired menu item here Ambient Conditions Press the L key ENTER to select the fourth level Level 4 Call up the menu item desired in the fourth level Use the RS keys to select t...

Page 14: ...ER SCALE Press the L key ENTER UNIT RS keys select DECIMALS GRAMS Press the L key ENTER o PT PD RS keys select STANDARD DECIMALS Press the L key ENTER o appears o STANDARD the desired setting is defin...

Page 15: ...sion to the PC is interrupted the lock symbol will be displayed The scale will automatically be locked preventing other weighing operations Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER...

Page 16: ...e password you must first correctly enter the old password under Password PW OLD will be displayed Following the correct input PW NEW will automatically appear You can now enter a new password or conf...

Page 17: ...s to select YES o NO Press the L key ENTER o will appear the new code is set Press the c key Clear several times to exit the menu Setting Codes Under the setting CODES the menu items are displayed in...

Page 18: ...ea changes constantly Too much vibration or the Access the menu to select scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu Setting...

Page 19: ...from AC power unplug the AC adapter power supply from the wall outlet mains supply Lock the equipment in a secure place to ensure that it cannot be used for the time being Safe operation of the PMA i...

Page 20: ...no Sartorius affiliates subsidiaries dealers or distributors are located please contact your local authorities or a com mercial disposal operator Prior to disposal and or scrapping of the equipment an...

Page 21: ...rface PMA Net RJ 45 10Base T 100Base TX Factory setting IP Address 192 168 140 016 Gateway 192 168 140 001 Subnet mask 255 255 255 000 Port 21554 Specifications Model PMA7501 000G 000GL Weighing range...

Page 22: ...rement con trol and laboratory use EMC requirements Part 1 General requirements Defined immunity Industrial areas continuous un moni tored operation to interference see Installation Instructions Limit...

Page 23: ...23...

Page 24: ...ingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG The status of the informat...

Reviews: