36
Operating Instructions PMA 35001-X
Verification of Intrinsic Safety
Page
5
of
2
36953-761-60
Verification of Intrinsic Safety
2013-05-02
Dr. D. Klausgrete
Revision 00
PMA35001-X..
Zone 1
Gas: IIC T4
Note:
1: For circuits with V
s
< 375V
2: Bus bar
A: Connection to main printed circuit board (PCB) 1 in YPSC01-.
B: Connection to main PCB 2 in YPSC01-.
2)
2)
Mains cable
1)
Hazardous Area
Non-Hazardous Area
Alternative
connections
Circuit
Ui
Ii
Pi
Ci
Li
V_1
12.6 V
133 mA
1.46 W
188 nF
0 mH
V_2
12.6 V
133 mA
1.46 W
3 nF
0 mH
V_3
8.6 V
187 mA
1.51 W
391 nF
0 mH
V_4
12.6 V
150 mA
1.68 W
223 nF
82 µH
2)
Power Supply
YPSC01-X /YPSC01-Z:
Circuit Uo
Io
Po
Co
Lo
V_1
12.6 V
115 mA
1.45 W
0.5 µF
350 µH
V_2
12.6 V
115 mA
1.45 W
0.5 µF
350 µH
V_3
8.6 V
168 mA
1.45 W
0.88 µF 350 µH
V_4
12.6 V
134 mA
1.68 W
0.5 µF
350 µH
V_5*
8.6 V
168 mA
1.45 W
0.88 µF 350 µH
*: not used
Any suitable intrinsically
safe Sartorius Equipment
A)
B)
A)
B)
Sartorius cable; permanently
mounted on the power supply;
cable can be flexibly installed;
max. length: 50m
Alternative
connection
2)
YPSC01-X
Power supply (100-240 Vac)
II 2 G
Ex e mb[ib] IIC T4
II 1D (2)G Ex tD A20 [ib]IIC
IP6X T130°C
YPSC01-Z
Power supply
(100-240 Vac)
II (2) GD [Ex ib] IIC
PMA35001-X..
II 2 G Ex ia IIC T4 Gb
Summary of Contents for PMA.Power Series
Page 29: ...Operating Instructions PMA 35001 X 29 EC Declaration of Conformity...
Page 30: ...30 Operating Instructions PMA 35001 X ECDeclaration of Conformity...
Page 32: ...32 Operating Instructions PMA 35001 X EC Verification...
Page 33: ...Operating Instructions PMA 35001 X 33 EC Verification...
Page 34: ...34 Operating Instructions PMA 35001 X EC Verification...
Page 40: ...40 Operating Instructions PMA 35001 X Certificate of Compliance...
Page 41: ...Operating Instructions PMA 35001 X 41 Certificate of Compliance...
Page 42: ...42 Operating Instructions PMA 35001 X Certificate of Compliance...
Page 43: ...Operating Instructions PMA 35001 X 43 Certificate of Compliance...