background image

14

Important Menu Settings

§

Hold down the 

L

key [ENTER] for approx. 2 sec. “SETUP” will appear on the display (Level 1).

Level 1

SETUP

Language Settings

Level 1

Level 2 

LANGUAGE

§

Press the 

R

key to select “

LANGUAGE”

§

Press the 

L

key press [ENTER] 

o

GERMAN

§

Press the 

RS

keys to select a language

ENGLISH

§

Press the 

L

key [ENTER]: “o” appears; 

FRENCH

the desired setting is defined. 

ITALIAN

§

Press the 

c

key (Clear) several times to

etc.

exit the menu.

Standard Basic Setting (0.1 g) / PolyRange (0.05 g / 0.1 g) and grams / PT./LB.

When you turn on the scale, the active basic setting is found under: 
“SETUP- SCALE – UNIT” and “SETUP- SCALE – DECIMALS”: 
Level 1

Level 2 

Level 3 

Level 4

SETUP

§

Press the 

L

key [ENTER] 

SCALE

§

Press the 

L

key [ENTER] 

UNIT

§

Press the 

RS

keys to select 

“DECIMALS” 

GRAMS

§

Press the 

L

key [ENTER] 

o

PT./LB.

§

Press the 

RS

keys to select 

“STANDARD”

DECIMALS

§

Press the 

L

key [ENTER], “o” appears; 

STANDARD

the desired setting is defined. 

POLYRANGE

§

Press the 

c

key (Clear) several times to 

exit the menu.

Activating the 

Toggle Key; Configuring (Basic Setting)

After the toggle key, I, has been activated, you can individually configure it with either 1 or 2 decimal
places, as well as with grams or PT./LB. 
Level 1

Level 2 

Level 3 

Level 4

SETUP

§

Press the 

L

key [ENTER] 

APPLICATION

§

Press the 

RS

keys to select 

“APPLICATION” 

§

Press the

L

key press [ENTER]

TOGGLE

§

Press the

RS

keys to select “TOGGLE” 

OFF

§

Press the

L

key [ENTER], 

o

ON

§

Press the

RS

keys to select “ON”.

§

Press the 

L

key [ENTER], “o” appears; 

the desired setting is defined. 

§

Press the 

c

key (Clear) several times to 

exit the menu.

Summary of Contents for PMA7501-000W

Page 1: ...98648 014 21 Installation Instructions Sartorius PMA Quality PMA7501 PMA7501 000W Electronic Paint mixing Scales...

Page 2: ...xing applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Display 11 Weighing pan 12 Interfaces D Sub connector 9 contact 13...

Page 3: ...ased device drivers to generate application programs Note Read the installation and operating instructions carefully before connecting the weighing platform and putting it into operation The applicati...

Page 4: ...y damage or injuries that occur when using cables not supplied by Sartorius When connecting the scale to the power supply the laws valid in your country must be observed If you should have any questio...

Page 5: ...lied Scale Weighing pan AC adapter or power supply 2 protective plugs in the column Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibratio...

Page 6: ...hat the voltage rating of the AC adapter matches that of your local line voltage mains supply If it does not match your local voltage rating or if the plug design differs from your local standard cont...

Page 7: ...ntil the desired weight of your formula is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan Otherwise...

Page 8: ...symbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you tare the scale a...

Page 9: ...ortant Note The flashing arrow n on the display means that the weight shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula the wei...

Page 10: ...or downwards using the S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you alread...

Page 11: ...key 4 several times to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 7 g 12 Pour in paint until 0 0 g is displayed 0 0 g 13 Press the L k...

Page 12: ...accuracy 0 075 g After connection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key...

Page 13: ...ess the L key ENTER to select the third level Level 3 The menu items in the third level Level 3 will be displayed Use the RS keys to select the desired menu item Press the L key ENTER to select the fo...

Page 14: ...key ENTER SCALE Press the L key ENTER UNIT Press the RS keys to select DECIMALS GRAMS Press the L key ENTER o PT LB Press the RS keys to select STANDARD DECIMALS Press the L key ENTER o appears o STAN...

Page 15: ...ill be displayed The scale will automatically be locked preventing further weighing operations Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER EXTRAS Press the RS keys to select EXTRAS Pre...

Page 16: ...Password PW OLD will be displayed Following the correct input PW NEW will automatically appear You can now enter a new password or confirm each blinking dash by pressing the L key ENTER Blank spaces...

Page 17: ...rst be entered Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER RESET Press the RS keys to select RESET Press the L key ENTER MENU Press the RS keys to select MENU Press the L key ENTER YES...

Page 18: ...er area changes constantly Too much vibration or Access the menu to select the scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu Se...

Page 19: ...mage to the AC adapter power supply The AC adapter power supply no longer functions properly The AC adapter power supply has been stored for a relatively long period under unfavorable conditions The e...

Page 20: ...not members of the European Economic Area EEA or where no Sartorius affiliates subsidiaries dealers or distributors are located please contact your local authorities or a com mercial disposal operator...

Page 21: ...ractive g 999 95 7500 Max linearity g 0 2 Stabilization time average digit 0 25 to 4 Moisture proof rating F Non condensing Allowable ambient operating temperature range C 0 to 40 Weighing pan d mm 23...

Page 22: ...as Defined immunity acc to product standard EN 61326 1 minimum require ments unmonitored operations Note The operator shall be responsible for any modifications to Sartorius equipment and for any conn...

Page 23: ......

Page 24: ...ingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG The status of the informat...

Reviews: