background image

3

 Contents

General View of the Equipment . . . . . .   2

Intended Use  . . . . . . . . . . . . . . . . . . .   3

Warnings and Safety Precautions   . . . .   3

Getting Started . . . . . . . . . . . . . . . . . .   6

Operation  . . . . . . . . . . . . . . . . . . . . . .   8

Applications  . . . . . . . . . . . . . . . . . . . . 10

Calibration/Adjustment . . . . . . . . . . . . 13

Menu Settings  . . . . . . . . . . . . . . . . . . 14

Troubleshooting  . . . . . . . . . . . . . . . . . 19

Care and Maintenance   . . . . . . . . . . . . 20

Recycling  . . . . . . . . . . . . . . . . . . . . . . 21

Interface Description . . . . . . . . . . . . . . 22

Specifications  . . . . . . . . . . . . . . . . . . . 22

Accessories  . . . . . . . . . . . . . . . . . . . . . 23

Documents . . . . . . . . . . . . . . . . . . . . . 24

Declaration of Conformity . . . . . . . . . . 24

  Intended Use

  The PMA7501-Y00G | -Y00GL (Series: 

PMA.World | PMA.Net) scales feature a 

graphic display and have been specially 

designed for use in paint-mixing appli-

cations. The PMA.Net is equipped with 

an Ethernet interface and can either be 

directly connected to the network inter-

face of a PC, or via a 10BaseT/100BaseTX 

LAN.

  This scale can be operated either using 

the keypad on the display and control 

unit (in “stand alone" mode) or using the 

application software (e.g., paint manu-

facturers' paint-mixing applications) 

installed on your PC. Communication is 

carried out via the data interface.

  If required, Sartorius can supply you with 

DOS- or WINDOWS®-based device drivers 

to generate application programs.

 

Note:

 

Read the installation and operating 

instructions carefully before connecting 

the PMA7501-Y... and putting it into 

operation.

 Note:

  Improper use or handling can result in 

property damage and/or personal injury. 

Only qualified personnel may install and 

operate the equipment. When operating 

the equipment in a potentially explosive 

atmosphere (Zone 2), make sure you 

observe the warnings and safety informa-

tion in their entirety during installation 

and operation, as well as while perform-

ing maintenance and repair work on 

the equipment (e.g.:  EN60079-14). The 

standards, regulations, occupational safe-

ty requirements and environmental pro-

tection laws valid in your country must 

be observed. It is important that all per-

sonnel using the equipment understand 

this warning and safety information, and 

have access to the relevant documents 

at all times. Furthermore, the warning 

and safety information supplied with any 

electrical equipment connected, such as 

peripheral devices, must be observed as 

well. The warnings and safety precau-

tions may have to be supplemented by 

the equipment operator. All operating 

personnel must be informed of any addi-

tions to these instructions. Make sure the 

equipment is accessible at all times.

  General Provisions for Installing the 

PMA7501-Y00G | -Y00GL

  The PMA7501-Y00G | -Y00GL mod-

els meet the requirements defined in 

EC Directive 94/9/EC for Class II, Cat-

egory 3D equipment and are suitable for 

operation in potentially explosive atmos-

pheres (Zone 2) in accordance with the 

KEMA05ATEX1248X EC type-examination 

certificate. Strictly observe the Safety Pre-

cautions in accordance with the diagram 

36457.741.20-A4 (refer to “Documents")!

  Furthermore, PMA7501-Y00G | -Y00GL 

models meet the EC Directives for elec-

tromagnetic compatibility and electrical 

safety (refer to the chapter on 

C

 Marking).

  Warnings and Safety 

Precautions

Summary of Contents for PMA7501-Y00G

Page 1: ...98648 015 13 Installation Instructions Sartorius PMA World PMA Net Models PMA7501 Y00G Y00GL Electronic Paint mixing Scales for Use in Hazardous Areas Zone 2...

Page 2: ...or paint mixing applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Graphic display 11 Weighing pan 12 Interfaces D Sub plug...

Page 3: ...t in a potentially explosive atmosphere Zone 2 make sure you observe the warnings and safety informa tion in their entirety during installation and operation as well as while perform ing maintenance a...

Page 4: ...2 Connect all equipment including peripheral devices to the equipotential bonding conductor Do not expose the scale to extreme tem peratures aggressive chemical vapors moisture shocks and vibrations T...

Page 5: ...ousing is made of PVC or rubber The allowable operating temperature range during operation is 0 C to 40 C 32 F to 104 F Make sure the place of installation is adequately ventilated to prevent build up...

Page 6: ...crew Strain relief for the Ethernet cable PMA7501 Y00GL only 2 protective plugs in the column Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture an...

Page 7: ...r supply the laws valid in your country must be observed If you should have any questions please contact your supplier or Sartorius Customer Service for information on the legal regu lations applicabl...

Page 8: ...til the desired weight of your formula is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan Otherwise y...

Page 9: ...mbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you zero the display b...

Page 10: ...ant Note The flashing arrow n on the display means that the weight shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula the weight...

Page 11: ...r downwards using the S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you already...

Page 12: ...he display 9 Press the y key 4 several times to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 7 g 12 Pour in paint until 0 0 g is displaye...

Page 13: ...onnection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key Center the calibration...

Page 14: ...d Use the RS keys to select the desired menu item here Ambient Conditions Press the L key ENTER to select the fourth level Level 4 Call up the menu item desired in the fourth level Use the RS keys to...

Page 15: ...ss the L key ENTER UNIT RS keys select DECIMALS GRAMS Press the L key ENTER o PT LB RS keys select STANDARD DECIMALS Press the L key ENTER o appears o STANDARD the desired setting is defined POLYRANGE...

Page 16: ...ol will be displayed The scale will automatically be locked preventing other weighing operations Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER EXTRAS Press the RS keys to select EXTRAS P...

Page 17: ...rd PW OLD will be displayed Following the correct input PW NEW will automatically appear You can now enter a new password or confirm each of the six blinking dashes by pressing the L key ENTER Blank s...

Page 18: ...ss the L key ENTER o will appear the factory settings are restored MENU appears on the display Press the c key Clear several times to exit the menu Setting Codes Under the setting CODES the menu items...

Page 19: ...other area changes constantly Too much vibration or the Access the menu to select scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu...

Page 20: ...e damage to the AC adapt er power supply or cables The equipment no longer functions properly The equipment has been stored for a relatively long period under unfavorable conditions The equipment has...

Page 21: ...information about disposal and recycling options please contact your local service staff The partners listed on the following website can be used for disposals within the EU 1 Go to http www sartorius...

Page 22: ...e Data Interface PMA Net RJ 45 10Base T 100Base TX Factory setting IP address 192 168 140 016 Gateway 192 168 140 001 Subnet mask 255 255 255 000 Port 21554 Specifications Model PMA7501 Y00G Y00GL Wei...

Page 23: ...ct the data cables YCO12 YCO13 when no power is being supplied to either end of the respective cables Securely fasten the D SUB connector to the PMA7501 Y The data cables YCO12 YCO13 may only be utili...

Page 24: ...24 Documents...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32...

Page 33: ...33...

Page 34: ...ents GmbH Co KG Goettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius The stat...

Reviews: