  When connecting peripheral devices (printer, PC) to 

the RS-232 interface port of the scale (PMA7501-

Y00G), please ensure that the connector screws are 

securely tightened. 

 

Note:

 

Connecting Data Cables

$

  The PMA.Net series is equipped with an Eth-

ernet interface and can either be directly con-

nected to the network interface of a PC, or via a 

10BaseT/100BaseTX LAN.

 

The data interface port has a protective cap. If you 

are not using the data interface port, please replace 

the protective cap.

§

  Connect the Ethernet cable, and secure it with the 

provided strain relief. 

 

Operate the equipment (or scale) only with a cable 

protected by strain relief or, if no cable is connected, 

with the connector cap in place. 

 

Connection to AC Power

 

The equipment is powered through the AC adapter 

supplied. Make sure that the voltage rating printed 

on the AC adapter or power supply is identical to 

your local AC power rating. When connecting the 

scale to the power supply, the laws valid in your 

country must be observed. If you should have any 

questions, please contact your supplier or Sartorius 

Customer Service for information on the legal regu-

lations applicable in your country. Use only original 

Sartorius AC adapters! The use of AC adapters from 

other manufacturers, even if these units have a reg-

istered approval rating from a national testing labo-

ratory, requires the approval of a certified technician.

§

  Insert the right-angle plug into the DC jack (13) on 

the scale  

  

Note:

!

  When installing the scale in Zone 2 areas, connec-

tors may only be plugged in or disconnected with 

the power completely switched off in a currentless 

/ zero-voltage state. Disconnect the scale from AC 

power before connecting the AC adapter or periph-

eral devices (printer, PC), cables or electronic  

peripheral. 

§

  The scale may only be operated when you have fas-

tened the right-angle plug using the safety retainer. 

§

  Plug the AC adapter into an electrical AC power outlet. 

!

  Observe the safety instructions and warnings in this 

manual. Furthermore, please refer to the section on 

safety instructions in the chapter on  

“Documents." 

7

Summary of Contents for PMA7501-Y00G

Page 1: ...98648 015 13 Installation Instructions Sartorius PMA World PMA Net Models PMA7501 Y00G Y00GL Electronic Paint mixing Scales for Use in Hazardous Areas Zone 2...

Page 2: ...or paint mixing applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Graphic display 11 Weighing pan 12 Interfaces D Sub plug...

Page 3: ...t in a potentially explosive atmosphere Zone 2 make sure you observe the warnings and safety informa tion in their entirety during installation and operation as well as while perform ing maintenance a...

Page 4: ...2 Connect all equipment including peripheral devices to the equipotential bonding conductor Do not expose the scale to extreme tem peratures aggressive chemical vapors moisture shocks and vibrations T...

Page 5: ...ousing is made of PVC or rubber The allowable operating temperature range during operation is 0 C to 40 C 32 F to 104 F Make sure the place of installation is adequately ventilated to prevent build up...

Page 6: ...crew Strain relief for the Ethernet cable PMA7501 Y00GL only 2 protective plugs in the column Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture an...

Page 7: ...r supply the laws valid in your country must be observed If you should have any questions please contact your supplier or Sartorius Customer Service for information on the legal regu lations applicabl...

Page 8: ...til the desired weight of your formula is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan Otherwise y...

Page 9: ...mbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you zero the display b...

Page 10: ...ant Note The flashing arrow n on the display means that the weight shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula the weight...

Page 11: ...r downwards using the S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you already...

Page 12: ...he display 9 Press the y key 4 several times to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 7 g 12 Pour in paint until 0 0 g is displaye...

Page 13: ...onnection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key Center the calibration...

Page 14: ...d Use the RS keys to select the desired menu item here Ambient Conditions Press the L key ENTER to select the fourth level Level 4 Call up the menu item desired in the fourth level Use the RS keys to...

Page 15: ...ss the L key ENTER UNIT RS keys select DECIMALS GRAMS Press the L key ENTER o PT LB RS keys select STANDARD DECIMALS Press the L key ENTER o appears o STANDARD the desired setting is defined POLYRANGE...

Page 16: ...ol will be displayed The scale will automatically be locked preventing other weighing operations Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER EXTRAS Press the RS keys to select EXTRAS P...

Page 17: ...rd PW OLD will be displayed Following the correct input PW NEW will automatically appear You can now enter a new password or confirm each of the six blinking dashes by pressing the L key ENTER Blank s...

Page 18: ...ss the L key ENTER o will appear the factory settings are restored MENU appears on the display Press the c key Clear several times to exit the menu Setting Codes Under the setting CODES the menu items...

Page 19: ...other area changes constantly Too much vibration or the Access the menu to select scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu...

Page 20: ...e damage to the AC adapt er power supply or cables The equipment no longer functions properly The equipment has been stored for a relatively long period under unfavorable conditions The equipment has...

Page 21: ...information about disposal and recycling options please contact your local service staff The partners listed on the following website can be used for disposals within the EU 1 Go to http www sartorius...

Page 22: ...e Data Interface PMA Net RJ 45 10Base T 100Base TX Factory setting IP address 192 168 140 016 Gateway 192 168 140 001 Subnet mask 255 255 255 000 Port 21554 Specifications Model PMA7501 Y00G Y00GL Wei...

Page 23: ...ct the data cables YCO12 YCO13 when no power is being supplied to either end of the respective cables Securely fasten the D SUB connector to the PMA7501 Y The data cables YCO12 YCO13 may only be utili...

Page 24: ...24 Documents...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32...

Page 33: ...33...

Page 34: ...ents GmbH Co KG Goettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius The stat...

Reviews: