background image

 

Contents. 

 
 
 
 
 
 

Page 

Equipment Supplied 

Installation Instructions 

Startup 6 

Operation 7 

Calibration 9 

Balance Operating Program 

10 

Troubleshooting Guide 

13 

Accessories 14 

Specifications 15 

Summary of Contents for U 4100

Page 1: ...Sartorius Universal U 4100 U 4100 S U 4800 P U 6100 U 5000 D U 6100 D U 6100 S Electronic Precision Balances...

Page 2: ...ling foot U 4100 U 6100 U 6100 D only 4 Menu access switch for balance operating program 5 ON OFF Taste 6 CAL key 7 PRINT key functions only if balance has a built in interface 8 Tare control 9 Weight...

Page 3: ...3 Contents Page Equipment Supplied 5 Installation Instructions 5 Startup 6 Operation 7 Calibration 9 Balance Operating Program 10 Troubleshooting Guide 13 Accessories 14 Specifications 15...

Page 4: ...lations and Equipment of April 1986 it is hereby certified that the equipment delivered electronic precision balance model U 4100 U 4100 S U 4800 P U 6100 U 6100 D or U 6100 S is manufactured and test...

Page 5: ...ns Choose a suitable place to set up your balance lt should not be exposed to the following heat radiation aggressive corrosive substances vibrations drafts Your Sartorius Balance will provide accurat...

Page 6: ...e make sure that the voltage printed on this unit is identical to your local line voltage rating Plug the line cord into the power receptacle of the balance and plug the AC adapter into a wall outlet...

Page 7: ...w in the STANDBY mode and ready to operate without warmup POWER OFF The balance was disconnected from line power reconnection to line power power failure CAL The calibration function has been called I...

Page 8: ...armup the next time you switch it on After the power is turned on a test of all essential electronic functions is run automatically The self test ends with the readout 0 00 g O O g if the program code...

Page 9: ...end of the calibration procedure Internal Calibration onlyfortheU6100S Unload the balance and zero the display Press the CAL key 6 as soon as the display shows a zero readout C will now be displayed...

Page 10: ...balance turned off STANDBY state hold down the tare control 8 and simultaneously press the ON OFF key 5 Upon completion of the automatic self test release the tare control as soon as CH 5 is displayed...

Page 11: ...mbol that appears indicates the actual setting To change any settings C mode press the tare control as soon as the appropriate code appears Brief display of BUSY and the o symbol confirms your selec t...

Page 12: ...decimal OFF c 5 1 5 Ounces oz C 1 3 3 Last decimal at stability c 5 1 6 Troy ounces ozt C 1 3 4 All decimals at stability C 5 1 7 Parts pound o c 5 2 1 Hong Kong taels tl Code Tare Parameter c 5 2 2...

Page 13: ...to adjust the proper code for the particular type of weighing environment Weight shows CE The Cal key 6 was not pressed when the display read zero The balance is loaded Press the tare control 8 Unload...

Page 14: ...e incl interface Over under checkweighing sorting classification Mass unit conversion Weight of residue in change in Statistics Net total formulation compounding Filling toward 0 Parts counting Animal...

Page 15: ...plication requirements by selection of 4 optimized filter levels Stability range d 0 25 64 selectable Ambient temperature range K 273 313 0 o C 40 o C Sensitivity drift within 283 303 K K 5 10 6 K 2 1...

Page 16: ...ication requirements by selection of 4 optimized filter levels Stability range d 0 25 64 selectable Ambient temperature range K 273 313 0 o C 40 o C Sensitivity drift within 283 303 K K 5 10 6 K 5 10...

Page 17: ......

Page 18: ...Copyright by Sartorius AG G ttingen Deutschland All rights reserved No part of this publication may be printed or translated in any form or by any means without the prior written permission of Sartori...

Reviews: