Installing the Instrument and Plug-in Cards
X3 Operating Manual
30
Sartorius
3.4.6 PR 5510/08 BCD Output (Open Emitter)
The plug-in card is used for BCD-coded output of a 5-decade weight value.
Cyclical output of the weight value with 4-bit (plus or minus sign, stability, error). The value is intrinsically
consistent and can be output continuously or the digital input DATA_IN control can be used to freeze (hold)
the value.
Internal connection:
34-contact female connector on flat
cable for Slot 1, 2
Number of outputs:
5 digits BCD + plus or minus sign
Number of inputs:
Input: 1 bit (DATA IN)
Output stage:
Common collector at +Uext.,
open emitter
External supply:
+5 V ... +24 VDC
Voltage drop:
Approx. 1.7 V
Output current:
Max. 50 mA
Enable input:
5 V / 24 V adjustable via S101
@ 5 V high > 3.1 V, low < 1.5 V
@ 24 V high > 16 V, low < 10V
protected against incorrect polarity
Cable:
Shielded, max. 50 m
Electrical isolation:
No
External connection:
X102
26-contact D-Sub connector (female)
Dimensions
(LxWxH):
60x106x22
Accessories (delivered
with the unit):
26-pin D-Sub mating plug (male)
incl. shielded housing
Weight:
55 g
Before installing the card, set switches S101 and S102; see Chapter 3.4.7.1.
Summary of Contents for X3 PR 5410
Page 14: ...Process Indicator X3 Operating Manual 14 Sartorius 2 3 6 Overview of Accessories ...
Page 144: ......
Page 147: ......