- 17 - 

 

sticking during combustion process, it may lead to agglomeration and slug forming in 

the  area  of  retort  rim  and  combustion  chamber  wall.  In  such  a  case,  the  obstacle 

should be pushed down into an ash drawer. Systematic maintenance extends boilers 

life and its auxiliary equipment. Cleaning the chimney duct is not less important.  

 

NOTE: At  least a month the quantity of slung in retort should be controlled. If 

required, put out a boiler and clean retort-furnace. 

 

6.4. 

END OF HEATING SEASON

 

 

Once  heating  season  is  finished,  or  when  switching  off  the  boiler  is  scheduled,  the 

controller should be then switched off and the glowing batch should be removed from 

retort and push into ash box chamber.  

Once  boiler  is  out  and  cooled  down,  remove  from    the    furnace    all    remains    of 

burned fuel and  apply  cleaning  and  conservation  of  the  entire boiler. Pay special  

attention  to  lubricate  inner  partitions  of  combustion  chamber  and  all  movable 

elements with oil.  

For  the  period  of  brake  time,  water  should  not  be  drained  out  of  boiler  and  

installation. In the controller manual mode, switch on a feeder allowing it to slide the 

glow into ash container.  

If    the  boiler  is  not  employed,  once  a  week  a  feeder  mechanism  should  be  put  to 

work. This preserve the screw elements not to be blocked inside a pipe. 

 

NOTE: it is not allowed to put out the fire with water when in the boiler’s room!

 

 

 

6.5. 

TERMS OF SAFE EXPLOITATION

  

 

In order to maintain safe operation of boiler following rules  need to be exercised: 

 

keep    the    boiler    in    good    technical    condition    and    its    installation,    in  

particular  take  care  of  the installation tightness, as well as keep sealed  door 

and washout openings,

 

 

keep boiler room tidy, do not stack any objects not related to boiler’s operation,

 

Summary of Contents for MULTI Series

Page 1: ...M E T A L O W O K O T L A R S K I 28 100 Busko Zdr j Owczary ul Przemys owa 3 Phone 48 41 378 46 19 Fax 48 41 370 83 10 TECHNICAL START UP DOCUMENTATION of water boilers for heating installations SAS...

Page 2: ...tallation 15 6 Operation and exploitation guidelines 16 6 1 Filling with water 16 6 2 Firing up and functioning of a boiler 16 6 2 1 Firing up and functioning of a boiler in automatic mode 17 6 2 2 Fi...

Page 3: ...3...

Page 4: ...ater temperature does not exceed 85 C and working pressure does not exceed 1 5 bar Required gases draught pressure after a boiler is 0 30 0 45 mbar depending on boiler s power These boilers may also w...

Page 5: ...in the temperature set on the controller The controller constantly measures the temperature of water boiler Depending on the results it controls fuel feeder and ventilator At the same time the control...

Page 6: ...arge cleaning door pos 6 furnace door pos 11 and ash box door pos 13 are placed on the boiler s front For periodic cleaning operations and also for firing up a boiler the retort may be accessed throug...

Page 7: ...1200 1280 A1 mm 290 290 305 305 330 330 B mm 1110 1235 1235 1300 1300 1300 B1 mm 450 535 535 605 605 605 H mm 1430 1430 1490 1490 1590 1590 H1 mm 1300 1300 1375 1375 1475 1475 H2 mm 980 980 1050 1050...

Page 8: ...door 14 air intake dosage flap 15 air draft regulator 16 connecting strip 17 hot water connector pipe 18 upper washout hole cover 19 smoke conduit clearing hole 20 smoke throttle 21 smoke conduit 22...

Page 9: ...tent to 10 Ash melting temperature 1150 C Low coal swelling coal should not tend to stick when burner Volatile particles content 30 40 It is recommended to use coal which is prone to agglomeration cok...

Page 10: ...allation shall be installed must conform the requirements of detailed regulations being in force at the country of destination e g PN 87 B 02411 In particular the following requirements shall be fulfi...

Page 11: ...k draught may also cause or help in carbon black forming which is then settling down on the boiler s convection channels If the draught is too strong it will cause excessive air to draw into the retor...

Page 12: ...system provided with three or four pass valve The main advantage of such connection is boiler protection function against low temperature corrosion preventing it from premature wear If not satisfacto...

Page 13: ...d down 6 2 FIRING UP AND OPERATE A BOILER Before fuel fire up it is mandatory to check installation filling with water Water can t be frozen It must be checked also if there is no water leakage on boi...

Page 14: ...as varying fuel quality may cause the boiler to burn out If the fire is out during up phase the furnace should be cleaned and boiler s channels ventilated and the whole starting procedure must be rep...

Page 15: ...ve At the same time the controller operates the heating system circulation pump if such is provided Heat requirement in the heat installation is varying due to changing outdoor conditions such as the...

Page 16: ...t those adverse phenomena should go away During normal exploitation of boiler in the traditional combustion mode burning process is based on periodic refueling Single load of basic fuel is sufficient...

Page 17: ...of burned fuel and apply cleaning and conservation of the entire boiler Pay special attention to lubricate inner partitions of combustion chamber and all movable elements with oil For the period of br...

Page 18: ...ection channels walls disrupts proper heat transfer from the exchanger lowering this way an efficiency of device and increases fuel consumption 6 6 OPERATE AND MAINTENACE OF A FEEDER AND RETORT Feeder...

Page 19: ...nstallation improper functioning of controller or fan adjust controller s settings up to weather conditions or quality of fuel mainly feeder operation time and fuel delivery pauses should be changed t...

Page 20: ...oal reduce the set of fuel supply by 5 10 or increase blow in power Wait 20 30 minutes until such changes come to effect what should be deflected in change of fire state In order to ensure the failure...

Page 21: ...arried out by authorized team Before connecting a boiler to a heating installation make check if all boiler s components are in good working condition and that the boiler is fully equipped NOTE Boiler...

Page 22: ...on alterations made by user or other third parties will cause the warranty to be invalid 8 Application of reclamation should be addressed at manufacturer 9 Boiler replacement realized by manufacturer...

Page 23: ...umentation however basic described properties of the product shall be maintained Any remarks and questions on boiler s SAS type exploitation shall be addressed ZAK AD METALOWO KOTLARSKI Owczary ul Prz...

Page 24: ...24 SERVICE REPAIRS...

Page 25: ...25 SERVICE REPAIRS...

Page 26: ...perature boiler of SAS MULTI type installed and operated in pursuance of Technical Start Up Documentation Boiler no Heating capacity Heated surface Year of manufacture Manufacturer signature and stamp...

Reviews: