Accessories:
To extend the utility of the Full face Supplied-Air respirator, the following accessories are offered as option
equipment.
Opti-Fit Fullface
Spectacle Kit
7622-60
Lens Cover Clear
7600-95
Lens Cover Shade
7600-96
PREPARATION FOR USE
Air Supply:
A. PURITY
Unless safety and health codes in your area specify otherwise, air purity must meet the requirements
of Type 1, Grade D gaseous air set forth in the Compressed Gas Association Commodity
Specification for Air, G-7.1. The responsibility of maintaining the quality of the air is yours. Install
purification and monitoring equipment as necessary.
B. PRESSURE
Pressure relief valve on SAS pump is factory set for maximum air flow. Pressure of the air supply
must be maintained within the range specified for the length of air supply line, measured at the inlet to
the air supply line. Refer to respirator manufacturer's recommendation for specific settings.
WARNING
If a compressor is used to supply breathing air, the following precautions must be taken:
A.
The compressor air intake must be located so that only clean, fresh air is drawn into the
compressor. Be especially careful that toxic gases are not drawn in. Locate the air intake
away from engine exhausts, spray paint exhausts, over spray, chemical processes,
and/or dust sources.
B.
The responsibility for compliance with safety and health codes, applicable to you area,
is YOURS.
LENGTH OF HOSELINE
The length of hoseline to be used will be determined by the job to be done. In
NO
case may the hose
length exceed 100 feet.
OPERATING INSTRUCTIONS
Donning:
1. Connect the air supply hose to the air supply.
2. Put the waist belt on. tighten the belt snugly around your waist.
3. Tuck the Full face mask under your arm and attach the clip-on end of the low pressure hose
(downtube) coming from your mask to the ring on your waist belt. Attach it so the plug on the end of
the hose pints rearward.
14