User’s manual
14
V.9.
Operation modes
V.9.a)
House heating
When this function is selected, only the house is heated. CH pump is activated when the temperature is
above the pump activation threshold (factory setting). Below this temperature value (minus 2
O
C –
hysteresis)
the pump is disabled.
V.9.b)
Water tank priority
In
this mode,
the DHW pump is activated first and it operates until the pre-set DHW temperature is
reached. After the pre-set temperature has been reached, the pump is switched off and the CH pump is
activated.
CH pump operates continuously until the water tank temperature drops below the pre-set value
minus
DHW
hysteresis
. Then, the CH pump is disabled and the DHW pump is activated.
In this mode, the fan and the feeder operation is limited to 72
O
C at the CH boiler in order to prevent the
CH boiler from overheating.
WARNING:
Return valves
should be installed on the circuits of the CH and DHW pumps. The valve on
DHW pump prevents hot water from being sucked out of the water tank
.
V.9.c)
Parallel pumps
In this mode, both pumps are activated simultaneously above the pre-set activation temperature (default
setting: 40 ºC).
CH pump operates all the time whereas DHW pump is disabled when the pre-set water tank temperature
is reached.
V.9.d)
Summer mode
In this mode, CH pump is switched off and DHW pump is enabled above the pump activation threshold
(default setting: 40OC) and operates all the time above this threshold.
In summer mode the user defines only the pre-set temperature of the CH boiler which heats the
domestic hot water (this value also serves as the pre-set water tank temperature). After this function
has been activated, the screen displays current CH temperature and two DHW temperature values (the
current temperature value and the pre-set one).
V.10.
Weekly control
Weekly control function enables the user to program changes of the pre-set CH boiler temperature
(CH weekly control) or water tank temperature (DHW weekly control) for particular hours and days of
the week.
In order to activate this function, select mode 1 or mode 2. Detailed settings of each mode are
available further in the submenu:
Set mode 1
and
Set mode 2.
Once a given mode is selected, the main screen displays the value of current temperature deviation
(below the pre-set CH temperature, alternately with
Pre-set
) informing the user that the function is
active.
How to change weekly control settings:
ST-491 controller enables the user to program weekly control function in two modes:
MODE 1 – the user sets the temperature deviations for each day of the week separately;
MODE 2 – the user sets the temperature deviations for all working days (Monday-Friday) and for the
weekend (Saturday-Sunday) separately.
How to configure mode 1:
In order to configure mode 1, select
Set mode 1
– the display shows the panel with particular days of
the week.
Once a given day of the week is selected, the screen shows the editing panel – the upper line shows
current deviation, the lower line shows the time period. Twist the pulser knob to change the time
period. In order to edit the deviation value, press the pulser knob and select
Change
.
In order to copy the setting for the next time period, press the pulser knob and select Copy.