background image

 

 

- 8 - 

2) Press CONFIG for entering configuration menu, change setting according to following figure. For 

resume factory default setting, press 

RESET

 and then confirm by pressing 

DONE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1H 2H HP1 HP2 Press  Display 

factory 

default 

Press Up and DOWN

To select 

Comments 

   1 NEXT 

STEP 

Mode

ALL

 

ALL/HO/CO 

ALL

heat and cool 

HO: heat 

CO: cool 

   2 NEXT 

STEP 

SYSTEM 

(2H) 

1H,2H,HP1,HP2 

Select control system 

   3 NEXT 

STEP BLowER 

(HA) 

HA,HE 

HA: Gas heating, Furnance 

controls blower 

HE: Electric heating. 

Thermostat controls blower 

   4 NEXT 

STEP 

AUMOdE 

HA

 

HA,HE 

HA: Fossil fuel backup heat 

HE: Electric backup heat 

NA NA  

NEXT 

STEP 

CHANGE 

(0) 

0,1 

0: Manual changeover 

1: Auto changeover 

   6 NEXT 

STEP 

DbaNd(3) 2,3,4,5,6,7,8,9 

Auto changeover dead band 

   7 NEXT 

STEP 

RECVRY 

(OF) 

OF/ON 

Intelligent Recovery 

operation 

   8 NEXT 

HCYCLE 

1,2,3,3,5 

First heating cycle rate 

Press 

DOWN

to confirm and 
exit 

Press 

CONFIG

for entering 
configuration menu

Press 

CANCEL

to exit to main 

home screen

Press 

NEXT 

STEP changing to 
next menu item

Display menu item

Press 

UP

 and 

DOWN

for change setting 

Press 

DOWN

to confirm and 
exit 

Press 

RESET

for resume to
factory default 
setting

Press 

PREVIOUS 

STEP changing to 
previous menu 
item

Press 

CANCEL

to exit to main 

home screen

Summary of Contents for SAS6000UTK-7

Page 1: ...Auto change over Permanent user setting retention during power loss no batteries are required Optional 7 day programming and non programmable Optional temperature display of Celsius or Fahrenheit sca...

Page 2: ...rmostat Home Screen Description Figure 2 Figure 1 Time of the day System Switch Fan Swtich Menu key for entering different modes Date of Week Set Temperature Room Temperature Temperature Up Down used...

Page 3: ...s CLEAN DISPLAY for entering 30 second count back time for cleaning the display Press PREVIOUS STEP for going back to last configuration menu item 9 Press SET SCHED for setting schedule for each days...

Page 4: ...xpired INSTALLATION 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit 2 Place base over hole in wall and mark mounting hole locations...

Page 5: ...y Y Compressor contactor G Fan relay C S1 24VAC common remote sensor 3 4 S2 Remote sensor RC Power 1 RH RH RC joined by jumper W Heat Relay Y Compressor contactor G Fan relay C S1 24VAC common remote...

Page 6: ...ing B Changeover valve energized in cooling G Fan relay C S1 24VAC common remote sensor 3 S2 Remote sensor L Equipment monitor 5 RC Power 1 RH RH RC joined by jumper Y1 Compressor relay 1 E Emergency...

Page 7: ...there is no emergency heat relay CONFIGURATION MENU The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements To enter the configur...

Page 8: ...T STEP AUMOdE HA HA HE HA Fossil fuel backup heat HE Electric backup heat NA NA 5 NEXT STEP CHANGE 0 0 1 0 Manual changeover 1 Auto changeover 6 NEXT STEP DbaNd 3 2 3 4 5 6 7 8 9 Auto changeover dead...

Page 9: ...elect second stage cooling rate 18 NEXT STEP FILTER 00 00 12 Select filter replacement run time 19 NEXT STEP UVLAMP UF UO or UF Select UV lamp replacement run time 20 NEXT STEP CLOCK 12 24 12 Selectio...

Page 10: ...ecovery operation The thermostat has an intelligent recovery function that brings your room temperature to the set temperature at exactly the pre set time by turning on the heating earlier Select ON t...

Page 11: ...1 HP2 2H setting in system type option Second stage heating rate Second stage heating will activate Hcycle H2sp below first stage heating 16 Select second stage cooling rate This option apply only to...

Page 12: ...en remote sensor option menu item 20 is set 2 0 No heat pump compressor lockout 15 20 25 30 35 40 heat pump compressor lockout temperature With fossil fuel backup See menu item 3 Auxiliary heat type o...

Page 13: ...onal air cleaning Choose the System Setting Cool Off Heat Emer Auto Press the SYSTEM button to select Heat Thermostat controls only the heating system Cool Thermostat controls only the cooling system...

Page 14: ...am schedule What ever temperature you set will be maintained 24 hours a day until you manually change it or press RUN SCHED to cancel Hold and resume the program schedule Vacation Hold Override This f...

Page 15: ...set to 1 or 2 INFO will display in home screen Press INFO for inquiring outside temperature Thermostat will display outside temperature Inquiry for filter count back time This operation is only avail...

Page 16: ...e configuration menu item 6 Intelligent Recovery operation Compressor protection See configuration menu item 10 Select compressor lockout delay Heat Pump Temperature Lockout See configuration menu ite...

Page 17: ...reset schedule press VIEW SCHED button Select 4 different time period for setting program schedule WAKE LEAVE RETURN SLEEP When viewing the program you can view the preset program schedule by selectin...

Page 18: ...rogram The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures Keep the following guidelines in mind when planning your program In Heating lower...

Page 19: ...19 CUSTOMER ASSISTANCE After reading this guide if you have any question about the operation of your thermostat please contact your installer or service provider...

Page 20: ...20...