background image

15 

Front side description – LED indicators and the button 

For easier use and understanding, the device has an LED indicator on the front side. The description of the indicators is 
described below. 

 

 

 

 

When there is communication 

going on between the control 

centre and the thermostat, the 

indicator on which the thermostat 

is connected – blinks twice. Here 

is also the indication for 

connection of the thermostats. 

When the heat 

source or the 

manifold pump is 

activated, this LED 

indicator turns on 

(red)*. 

When there is a need for 

heating, the indicator under the 

particular number (1-8) turns on 

(green). 

If the device is 

turned on or 

plugged in to 

power supply, the 

LED indicator 

turns red. 

* If there is no output on the exit 1-8 and are turned off, the next output on the heating source, pump, starts with a delay 
of 3-5 minutes. 

 Button 

With this button you can connect thermostats to the control centre. You can do that by holding this 

button for 3 seconds.  
You can also reset all the thermostat connections to the control centre.  You have to turn unplug the control centre out 

of the power supply and while plugging it back to the power supply, hold the button 

 and all the LED indicators 

should blink three times. 

Summary of Contents for SCU209DE

Page 1: ...1 SI Brez i na Centralna priklju na letev za talno ogrevanje ENG Wireless terminal strip centre for underfloor heating SASWELL SCU209DE Uporabni ki priro nik User manual...

Page 2: ...2 Compatible models T19WHB 7 DF SAS908XWHB 7 DF SAS816WHB 0 DF SAS918WHB 0 DF...

Page 3: ...etajlov tehnologije in izvedbe Garancija velja le skupaj z ra unom Dopu amo mo nost napak v besedilu Varovanje narave Elektronske naprave in baterije po koncu ivljenjske dobe ne odlagajte med me ane k...

Page 4: ...i gane sve ke ipd Izdelka ne postavljajte na mesta kjer ni zadostnega kro enja zraka V prezra evalne odprtine ne vtikajte nobenih predmetov Ne posegajte v notranjo elektri no napeljavo izdelka lahko g...

Page 5: ...vanja LED prikaz delovanja na izhodih Specifikacije enote Napajanje AC 100 240V 50 60Hz Temperatura okolice delovanja od 0 C do 50 C Skladi na temperatura od 10 C do 60 C Dimenzije 280x110x40mm Kontak...

Page 6: ...no pred samo nastavitvijo si zopet preberite vsa varnostna opozorila in izklopite glavno napajanje Po kon ani vezavi namestite zadnji del ohi ja s prilo enimi vijaki na eljeno mesto stena Ko ste oprav...

Page 7: ...klopov L Faza N Nula PE Ozemljitev RA1 do RA8 priklopi za posamezne termo glave oz upravljanje ogrevalnih vej prostorov Pump Priklop za obto no rpalko Boiler Brez napetostni kontakt za priklop ogreval...

Page 8: ...osvetli zeleno e je naprava pri gana oz ima napajanje se LED indikator osvetli rde e e na nobenem od izhodov od 1 5 ni potrebe po delovanju in so ugasnjeni se po ponovni potrebi delovanja ogrevalnega...

Page 9: ...a sedaj letev aka na paritev MASTER termostata za upravljanje prve ogrevalne zanke oz sobe ter ima tudi mo nost upravljanja vseh ogrevalnih vej e elite na kratko pritisnite tipko in boste pre li na t...

Page 10: ...rmance The guarantee is valid only with the original invoice We allow the possibility of errors in the text Environmental protection Do not place electronic products and batteries after the end of the...

Page 11: ...t place the product in places where there is insufficient air circulation Do not insert any objects into the ventilation openings Do not interfere with the internal electrical wiring of the product It...

Page 12: ...a 868MHz frequency Specifications Power supply 100 240V AC 50 60Hz Communication Wireless RF 868 MHz FSK half duplex RF range Up to 100m no obstacles Ambient temperature 0 C 50 C Transport and warehou...

Page 13: ...ns on the sides of the case and slowly remove the front part Now you have access to the electronic board Perform the electrical wiring by your needs and place the housing on the desired place on your...

Page 14: ...g description L Live N Neutral PE Grounding Earth RA1 do RA8 Connectors for each thermal actuators or heating zones Pump Connector for manifold pump Boiler Volt free contact for connecting a heating s...

Page 15: ...n there is a need for heating the indicator under the particular number 1 8 turns on green If the device is turned on or plugged in to power supply the LED indicator turns red If there is no output on...

Page 16: ...rmostats 2 8 are considered as slave thermostats and can control only their own heating circuits or none if they are overridden by the master thermostat So if you are in connectivity mode and you ve s...

Reviews: