Operating instructions SATA filter 400
2.4.
Filter cartridges
Type:
In case of extreme contamination, filters should be checked and, if necessary, replaced more frequently. The
sintered bronze filter (8) and the filter housing tube (7,11) must be cleaned every six months at the latest, if
necessary, replace sintered bronze filter cartridge. Saturated filter cartridges bear the danger of functional
defaults during painting resp. affecting the painter‘s health while using supplied-air respirator systems.
3. Technical data and specifications
- Air inlet G 1/2 inside thread
- Maximum inlet operating pressure 15 bar/225 psi; 1,5 MPa
for SATA filter 434; SATA filter 464 = 10 bar/150 psi; 1,0 MPa
- Maximum outlet operating pressure 10 bar; 1,0 MPa
- Air flow rated at 3600 NI/min (129,6 cfm) at 6 bar/90 psi
- Max: ambient temperature 120° C (248 F) with activated charcoal unit max:
ambient temperature 60 ° C (140 F)
Weight:
SATA filter 414
=
2,2 kg
SATA filter 414L
=
1,5 kg
SATA filter 424
=
2,7 kg
SATA filter 424L
=
2,0 kg
SATA filter 434
=
2,3 kg
SATA filter 434L
=
1,6 kg
SATA filter 464
=
2,3 kg
SATA filter 464
=
1,5 kg
(Add-on module)
Combination filter:
SATA filter 444
=
4,3 kg
SATA filter 444L
=
3,5 kg
SATA filter 474
=
3,9 kg
SATA filter 484
=
5,9 kg
SATA filter 494
=
6,6 kg
VIII.3
Sintered filter cartridge
5
μ
m, surface area 100 cm²,
solvent regenerable
Replacement interval every
six months
Art. No. 22160
Fine filter cartridge
, Polypropy-
lene Micro Fibre layer Surface area
300 cm² Filtering capacity 0,01
μ
m
99,998 % separation,
non-regenerable
Replacement interval every
six months, at the latest when
the maximum pressure diffe-
rence between inlet and outlet
pressure is 1 bar/14.5 psi
Art. No. 81810
Activated charcoal cartridge
non-regenerable
Replacement interval every
three months
Art. No. 85373
english
6718_Betriebsanleitung_filter_400.indd 45
6718_Betriebsanleitung_filter_400.indd 45
25.08.2008 14:09:00