background image

Operating Instructions SATA

®

 jet3000

®

 K spray mix

Prior to putting the unit/paint spray gun into operation, read the operating instructions completely 

and thoroughly. The stipulations contained therein are to be respected in any case. After that, the 

operating instructions are to be stored in a safe place, accessible for every user of the equipment. 

The unit/paint spray gun may only be put into operation by persons familiar with its use (professio-

nals). Inappropriate use of the unit/paint spray gun, modification of any kind or combination with 

inappropriate other parts may cause material damage, serious hazard to the user‘s, other person‘s 

or animal‘s health or even death. SATA shall not take any responsibility for such damages (e.g. 

failure to respect the stipulations laid out in the operating instructions). The applicable safety, 

workplace and worker health protection regulations of the respective country or area/district in 

which the system/the paint spray gun is used are to be respected in any case (e.g. the German 

Rules for the Prevention of Accidents BGR 500 issued by the Central Office of the Professional 

Trade Associations, etc.). SATA, SATAjet, the SATA Logo and/or other SATA products referenced 

herein are either registered trademarks or trademarks of SATA GmbH & Co. KG in the U.S. and/or 

other countries. The names of companies and products mentioned herein may be the trademarks 

of their respective owners.

Never point paint spray guns at yourself, at other persons or animals. Solvents and thinners can 

cause burns. Only the respective quantities of solvents and paints required for work progress may 

be present in the direct surroundings of the unit (after work, solvents and paints are to be returned 

to their assigned storage rooms). Prior to any repair work the unit must be disconnected from the 

air supply. Prior to putting the unit into operation, especially after each cleaning and each repair 

work, check all screws and nuts for tight fit, as well as the sealing performance of the spray guns 

and hoses. Defective components must be replaced or repaired accordingly. To obtain best pos-

sible coating results, and for maximum safety, only use original spare parts. No sources of ignition 

(e.g. open flames, burning cigarettes, lamps without ex-protection etc.) may be present during 

painting, as easily flammable mixture are generated during the painting process. Occupational 

safety regulations must be applied when painting (respiratory protection, etc.). Appropriate ear 

protection muffs are required, as a sound level of 90 dB(A) is exceeded when coating with higher 

pressure levels. No vibration is transmitted to the upper parts of the operator‘s body during use of 

the paint spray gun. Recoil forces are negligible. 

The use of this product in explosion hazard areas Zone 0 is prohibited.

To be noted

Preface

1. Scope of Delivery and technical Data (General)

english

IX.1

1.1 Scope of Delivery

a. Art. No.:  120 006

• 

SATAjet 3000 K spray mix, cpl. with paint 

tube and strainer (100 msh), all material 

passages are made of stainless steel. 

• 

The SATAjet 3000 K spray mix is equipped 

with: Round/flat spray control, air cap,  

pre-nozzle, paint needle tip with ball 

sealing made of hard metal as well as a 

trigger block avoiding erroneous trigger 

pulls and a tool kit.

• 

The paint nozzle is not included in the 

scope of delivery. It has to be ordered 

separately (see list on page 10 for selec-

tion).

b. Art. No.:  120 014

• 

SATAjet 3000 K spray mix, cpl. with inversion 

switch air cap

• 

Further equipment is listed under a.

• 

The inversion switch has to be ordered sepa-

rately (see list on page 10 for selection).

Summary of Contents for jet3000 K

Page 1: ...SATAjet 3000 K spray mix Betriebsanleitung Operating Instructions Mode d emploi Betriebsanleitung Operating Instructions...

Page 2: ...US 7 018 154 1 2 3 4 7 10 9 6 8 5...

Page 3: ...paints are to be returned to their assigned storage rooms Prior to any repair work the unit must be disconnected from the air supply Prior to putting the unit into operation especially after each clea...

Page 4: ...atomised by the compressed air which comes out of the air cap at the same time IX 2 3 Construction 1 Paint nozzle not within the scope of delivery 2 Self tensioning needle packing not visible 3 Trigg...

Page 5: ...e substrate and adjust pressure accordingly if necessary best obtained by using a combi fine filter unit with integrated pressure regulator for rough spray pressure adjustment Due to high pressure dro...

Page 6: ...cient pressure by means of the pressure regulator Adjust the recommended inlet pressure of 1 5 2 0 bar 22 29 psi at the micrometer Art No 27771 4 4 Correct adjustment of the dynamic inlet pressure Ill...

Page 7: ...Remove paint needle from spray gun body with a rotating movement If necessary also replace seal retainer 98525 Please make sure that the surface of the sealing is undamaged In case of damage please r...

Page 8: ...t position and tighten paint nozzle again Respect mounting instructions for the air distribution ring see 6 1 e Slightly oil movable parts with SATA special grease Art No 10009 IX 6 A mounting instruc...

Page 9: ...it again Make sure that the air distribution ring fits in tightly against the gun body 4 Mounting the nozzle set Proceed in the opposite sense as described under 1 Convince yourself of the flawless g...

Page 10: ...leaning needle Drop like or oval shaped pattern Dirt on fluid pin tip or air circuit clogged Turn air nozzle by 180 degrees If defective pattern remains clean fluid tip pin and air circuit Paint spray...

Page 11: ...ner holder 77503 and 1 screw 26393 94961 Air micrometer cpl 97824 Pack of 3 air distribution rings 98418 Closing screw 98434 Pre nozzle cpl 98459 Air cap cpl round flat fan 98525 Seal retainer cpl 985...

Page 12: ...25 14 0 30 2850 50906 0 28 0 011 50 22 0 30 2865 13771 0 28 0 011 65 25 0 30 3050 120238 0 30 0 012 20 50 14 22 0 38 100 msh 150 m 12278 Set of 4 3325 20206 0 33 0 013 25 14 0 45 3350 50898 0 33 0 013...

Page 13: ...be issued for the repair or replacement Replaced parts become the property of SATA or their distributor Notice of defects or other claims do not entitle the consumer to delay or refuse payment Return...

Page 14: ...98699 Gewicht Weight Poids mit with avec SATAjet 3000 K spray mix 650 g...

Page 15: ...SATA GmbH Co KG Domertalstr 20 70806 Kornwestheim Tel 49 71 54 811 0 Fax 49 71 54 811 196 www sata com 98715 4018 20...