background image

Operating Instructions SATAjet 3000 K spray mix

4. Putting into Operation

Before putting into operation, and especially after each cleaning and any repair work, check to see 

that all screws and nuts are tight. This especially applies to the closing screw, the round/flat spray 

control (pos. 5) and for the locking screw (pos. 11) of the air micrometer. The paint spray gun has 

been treated with an anticorrosive agent before leaving the factory and must therefore be flushed 

out thoroughly with thinner before use. For servicing/repair work of any kind, the system must be 

devoid of pressure, i.e. disconnected from the air supply. Failure to respect this safety warning 

may result in damage and injuries, even death at worst. SATA does not take any responsibility for 

possible results of such failure.

Material connection:

a) Connect material hose of pressure pot, respectively pump to the spray gun.

b) Adjust requested atomisation pressure with pulled trigger. Then adjust material feed pressure  

  with pulled trigger. Please check spray pattern on paper or other suitable substrate and adjust  

  pressure accordingly, if necessary.

...best obtained by using a combi fine filter unit with integrated pressure 

regulator, for rough spray pressure adjustment. Due to high pressure drop in 

the air hose/coupling, the actual dynamic air pressure should be checked and 

fine-adjusted at the spray gun air inlet.

Art. No. 92296

For maximum air flow, fully open integrated 

Micrometer

, i.e. put into vertical 

position III. By means of the variable adjustable air micrometer the internal 

spray gun presure can be set directly at the gun. Connect the spray gun to 

the air supply, pull the trigger and adjust the requested spray gun internal 

pressure.  

4.1 Clean Spray air

4.2 Sufficient air volume

4.3 Air micrometer

...obtained by an appropriate compressor, large air line diameters and, to 

avoid too much pressure drop, an air hose with minimum 9 mm inner diameter 

in antistatic and pressure-resistant version and free from substances affecting 

the painting result. Blow out the air hose before attaching it to the air connec-

tion (G 1/4 ext.). The air hose must be pressure-resistant for min. 145 psi and 

solvent-resistant. Total electric resistance: < 100 million Ohm. 

Art. No. 53090 (Length 10m) - 

(non-resistant against petrol and oil)

Illustration similar

english

IX.3

Summary of Contents for jet3000 K

Page 1: ...SATAjet 3000 K spray mix Betriebsanleitung Operating Instructions Mode d emploi Betriebsanleitung Operating Instructions...

Page 2: ...US 7 018 154 1 2 3 4 7 10 9 6 8 5...

Page 3: ...paints are to be returned to their assigned storage rooms Prior to any repair work the unit must be disconnected from the air supply Prior to putting the unit into operation especially after each clea...

Page 4: ...atomised by the compressed air which comes out of the air cap at the same time IX 2 3 Construction 1 Paint nozzle not within the scope of delivery 2 Self tensioning needle packing not visible 3 Trigg...

Page 5: ...e substrate and adjust pressure accordingly if necessary best obtained by using a combi fine filter unit with integrated pressure regulator for rough spray pressure adjustment Due to high pressure dro...

Page 6: ...cient pressure by means of the pressure regulator Adjust the recommended inlet pressure of 1 5 2 0 bar 22 29 psi at the micrometer Art No 27771 4 4 Correct adjustment of the dynamic inlet pressure Ill...

Page 7: ...Remove paint needle from spray gun body with a rotating movement If necessary also replace seal retainer 98525 Please make sure that the surface of the sealing is undamaged In case of damage please r...

Page 8: ...t position and tighten paint nozzle again Respect mounting instructions for the air distribution ring see 6 1 e Slightly oil movable parts with SATA special grease Art No 10009 IX 6 A mounting instruc...

Page 9: ...it again Make sure that the air distribution ring fits in tightly against the gun body 4 Mounting the nozzle set Proceed in the opposite sense as described under 1 Convince yourself of the flawless g...

Page 10: ...leaning needle Drop like or oval shaped pattern Dirt on fluid pin tip or air circuit clogged Turn air nozzle by 180 degrees If defective pattern remains clean fluid tip pin and air circuit Paint spray...

Page 11: ...ner holder 77503 and 1 screw 26393 94961 Air micrometer cpl 97824 Pack of 3 air distribution rings 98418 Closing screw 98434 Pre nozzle cpl 98459 Air cap cpl round flat fan 98525 Seal retainer cpl 985...

Page 12: ...25 14 0 30 2850 50906 0 28 0 011 50 22 0 30 2865 13771 0 28 0 011 65 25 0 30 3050 120238 0 30 0 012 20 50 14 22 0 38 100 msh 150 m 12278 Set of 4 3325 20206 0 33 0 013 25 14 0 45 3350 50898 0 33 0 013...

Page 13: ...be issued for the repair or replacement Replaced parts become the property of SATA or their distributor Notice of defects or other claims do not entitle the consumer to delay or refuse payment Return...

Page 14: ...98699 Gewicht Weight Poids mit with avec SATAjet 3000 K spray mix 650 g...

Page 15: ...SATA GmbH Co KG Domertalstr 20 70806 Kornwestheim Tel 49 71 54 811 0 Fax 49 71 54 811 196 www sata com 98715 4018 20...

Reviews: