10. Trouble-shooting
Malfunction
Cause
Corrective Action
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
suction cup
Fluid tip has not been
properly tightened
Tighten fluid tip
[2-1]
with universal spanner
[7-4]
Air distribution ring is
damaged or clogged.
Replace air distribution
ring which will be dam-
aged during extraction
Air bubbles appearing
in the suction cup
Loose air cap
Tighten air cap
[2-2]
by hand
Gap between air cap
and fluid tip ("air cir
-
cuit") is clogged
Clean air circuit, ob-
serve chapter 8
Nozzle set is clogged
or damaged
Clean the nozzle set,
chapter 8, or replace,
chapter 9.1
Not enough paint ma-
terial in the suction cup
Refill suction cup
Defective paint needle
seal
Replace the paint nee-
dle seal, chapter 9.3
Spray pattern is too
small, crooked, lop-
sided or splitting
Clogged air cap drill-
ings
Clean air cap, observe
chapter 8
Damaged fluid tip (fluid
tip aperture)
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
No function of round/
flat spray control - con
-
trol knob can still be
turned
Air distribution ring has
not been positioned in
correct location (pin is
not located in the drill-
ing) or damaged
Replace the air dis-
tribution ring making
sure it has been posi-
tioned correctly when
inserting it, chapter 9.2