114
EN
Operating instructions SATAminijet 1000 K/H RP/HVLP
Notice!
Ensure the following conditions:
• Use a compressed air connection G 1/4 male thread or a fitting SATA
connection nipple.
•
Ensure minimum air volume (air consumption) and pressure setting
(recommended spray gun inlet pressure) according to chapter 2.
• Ensure clean compressed air, e.g. by installing a SATA filter 100,
Art.
No. 148247, outside the spray booth
or a SATA filter 484,
Art. No.
92320 inside the spray booth
•
Use an air hose with minimum 6 mm inner diameter (see warnings),
e.g.
Art. No. 53090
.
1. Check if all screws
[2-1]
,
[2-2]
,
[2-3]
,
[2-4]
and
[2-5]
have been
tightened firmly. Tighten fluid tip
[2-1]
firmly by hand (12 Nm) accord
-
ing to
[7-4]
. Check if locking screw
[2-5]
has been firmly tightened
according to
[10-1]
. Tighten, if necessary.
2. Adjust air cap: vertical spray fan
[2-6]
, horizontal spray fan
[2-7]
.
3.
With SATAminijet 1000 K RP/HVLP:
Connect the material hose of
the tank or pump to the spray gun material connection.
With SATAminijet 1000 H RP/HVLP:
Connect the suction cup,
e.g. SATA RPS 0.3 l cup w/ RPS adapter, to the material connection
[1-3]
. When using a RPS 0.3 l suction cup set, first locate the plastic
insert into the neck of the RPS cup lid from above before pressing in
the pick-up tube from underneath ensuring that it is flush with the top
of the insert. Then plug the strainer onto the bottom end of the pick-up
tube prior to connecting the lid to the adapter. Finally, screw the filled
RPS cup onto the cup lid.
4. Screw connection nipple
[2-8]
onto the air inlet.
5. Connect compressed air hose
[2-9]
.