4. Putting into Operation
Before putting into operation, and especially after each cleaning and any repair work,
check to see that all screws and nuts are tight. This applies in particular for the material flow
control screw (counter nut), the round/flat spray control as well as the hexagon screw, pos.
3624, for the air micrometer. The paint spray gun has been treated with an anticorrosive agent
before leaving the factory and must therefore be flushed out thoroughly with thinner before use.
For servicing/repair work of any kind, the system must be devoid of pressure, i.e. disconnected
from the air supply. Failure to respect this safety warning may result in damage and injuries,
even death at worst. SATA does not take any responsibility for possible results of such failure.
...best obtained by using
a combi fine filter unit with integrated
pressure regulator
, for rough spray pressure adjustment. Due to high
pressure drop in the air hose/coupling, the actual dynamic air pressure
should be checked and fine-adjusted at the spray gun air inlet.
part. no. 92296
For maximum air flow, fully open integrated Micrometer, i.e. put into verti-
cal position III (not necessary when using a DIGITAL 2 version).
Pressure can be adjusted directly at the spray gun. By means of the
variable adjustable air micrometer the spray gun internal pressure can be
set. Connect the spray gun to the air supply, pull the trigger and adjust
the requested spray gun internal pressure.
4.1. Clean spray air
4.2. Sufficient air volume
4.3. Air micrometer
Note:
- Micrometer in vertical position (position III - parallel to the gun body) =
maximum atomization and maximum internal spray gun pressure (iden-
tical with spray gun inlet pressure).
- Position I or II (across gun body) = minimum atomization, minimum
internal spray gun pressure (for Spot Repair, speckling, etc.)
Attention: While the spray gun is connected to the air supply, the
air micrometer fixing screw, pos. 3624, must not be removed. When
the fixing screw is removed, the spray gun must not be put into
operation.
!
...obtained by an appropriate compressor, large air line diameters and,
to avoid too much pressure drop, an air hose with minimum 9 mm inner
diameter in antistatic, silicone-free and pressure-resistant version. Blow
out the air hose before attaching it to the air connection (G 1/4 ext.). The
air hose must be pressure-resistant for min. 145 psi and solvent-resistant.
Total electric resistance: < 100 million Ohm, non-resistant against benzine
and oil.
part. no. 53090 (Length 10m)
Illustration similar
Illustration similar
VIII.3
SammelBAL_Jet2000_ohneLR.indd 66
SammelBAL_Jet2000_ohneLR.indd 66
26.01.2006 13:20:28
26.01.2006 13:20:28