4. Technical data
Nominal supply voltage (±15%) ................................................................................... 12 V DC
Current consumption, standby:
DG-1 CO ............................................................. 9-20 mA
DG-1 LPG ......................................................... 30-50 mA
DG-1 ME ........................................................... 30-50 mA
DG-1 TCM ....................................................... 80-120 mA
Current consumption, maximum:
DG-1 CO .................................................................20 mA
DG-1 LPG ...............................................................50 mA
DG-1 ME .................................................................50 mA
DG-1 TCM ............................................................. 120 mA
Relay contacts rated load (resistive) ............................................................... 40 mA / 16 V DC
Operating temperature range .................................................................................. -10...+55 °C
Dimensions ......................................................................................................... ø 97 x 36 mm
Weight:
DG-1 CO .................................................................... 63 g
DG-1 LPG .................................................................. 62 g
DG-1 ME .................................................................... 63 g
DG-1 TCM .................................................................. 64 g
The average life time of DG-1 detector is 5 years.