Fig. 4. Removing the cover.
2. Remove the electronics board.
3. Make suitable openings for screws and cable in the enclosure base.
4. Pass the cable through the prepared opening.
5. Fix the enclosure base to the ceiling.
6. Fasten the electronics board.
7. Connect the wires to the corresponding terminals.
8. Using jumpers, set the working parameters of the detector.
9. Close the detector enclosure.
2. Start-up
1. Switch the detector power on. The LED will start blinking (if the LED ON/OFF pins
are shorted).
2. When the detector is ready to work (the LED will stop blinking), carry out the
detector range test, i.e. check that movement within the supervised area will
activate the alarm relay and lighting of the LED.
3. If necessary, change the detector sensitivity (pins PIR SENS.).
3. Specifications
Supply voltage ................................................................................... 24 V AC/DC ±15%
Max. current consumption (±10%) .................................................... 27 mA for 24 V AC
....................................................14 mA for 24 V DC
Relay contacts rating (resistive load).................................................... 40 mA / 16 V DC
Alarm signaling time ................................................................................................... 2 s
Protected area:
when mounted at a height of 2.4m................................................36 m
2
when mounted at a height of 3.7m................................................80 m
2
Detectable motion speed................................................................................ 0.3...3 m/s
Environmental class according to EN50130-5............................................................... II
Operating temperature range .......................................................................-30...+55 °C